Reassessment of Glucose Effectiveness and Insulin Sensitivity From Minimal Model Analysis: A Theoretical Evaluation of the Single-Compartment Glucose Distribution Assumption
The DOI matches its Crossref record.
Abstract
Minimal model analysis with the frequently sampled intravenous glucose tolerance test provides an effective way to measure two important metabolic parameters in vivo under non-steady-state conditions: glucose effectiveness (SG) and insulin sensitivity (SI). Two questions regarding the validity of SG and SI have recently emerged. First, SG from the minimal model is suspected to be overestimated. Second, the occurrence of SI values indistinguishable from zero (“zero-SI”) is not negligible in large clinical studies, and its physiological meaning is uncertain. In this study, we examined the significance of the assumed single-compartment glucose distribution embedded in the minimal model on the estimation of SG and SI. A more accurate two-compartment model was constructed by incorporating insulin action on hepatic glucose output and uptake into a previously validated construction. The two-compartment results were compared with the one-compartment minimal model results. It was shown that the one-compartment assumption contributes to a systematic deviation of SG (slope = 0.54, y-intercept = 0.014 min−1; n = 195 simulations). However, SG from the minimal model was linearly correlated to SG determined from the two-compartment model (r = 0.996). The one-compartment assumption also contributed to the occurrence of zero S1 values for insulin-resistant subjects. A similar linear relationship was found between S1 estimated by both the minimal model and the two-compartment model (slope = 0.58, y-intercept = −0.57 × 10−4 min−1 per μU/ml, r = 0.998). In conclusion, SG and SI from the minimal model are not necessarily equivalent to values emanating from the more accurate two-compartment model. However, the very high correlation between one- and two-compartment results suggests that the minimal model-derived SG and SI are dependable indexes of in vivo glucose effectiveness and insulin sensitivity. Minimal model analysis' advantages of simplicity, minimal invasiveness, reasonable reflection of non-steady-state glucose kinetics, and cost-effectiveness could in many cases outweigh the structural bias introduced by the model simplification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Methods for clinical assessment of insulin sensitivity and β-cell function
Pacini, G., & Mari, A. (2003) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/s1521-690x(03)00042-3 · Cited by 308
Disposition Index, Glucose Effectiveness, and Conversion to Type 2 Diabetes
Lorenzo, C., Wagenknecht, L. E., Rewers, M. J., Karter, A. J., Bergman, R. N., Hanley, A. J. G., & Haffner, S. M. (2010) · Diabetes Care · doi:10.2337/dc10-0165 · Cited by 145
Self-citationCobelli, C., Bettini, F., Caumo, A., & Quon, M. J. (1998) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1998.275.6.e1031 · Cited by 74
Krudys, K. M., Dodds, M. G., Nissen, S. M., & Vicini, P. (2005) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00058.2004 · Cited by 30
Metadata
- Authors
- Ni, T.-C., Ader, M., & Bergman, R. N.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1997-11-01
- Volume
- 46
- Issue
- 11
- Pages
- 1813-1821
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2058361630
- Cited by
- 42
- References
- 0
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reassessment of Glucose Effectiveness and Insulin Sensitivity From Minimal Model Analysis: A Theoretical Evaluation of the Single-Compartment Glucose Distribution Assumption. https://app.cochat.ai/papers/10.2337/diab.46.11.1813
- The paper
- Ni, T.-C., Ader, M., & Bergman, R. N. (1997). Reassessment of Glucose Effectiveness and Insulin Sensitivity From Minimal Model Analysis: A Theoretical Evaluation of the Single-Compartment Glucose Distribution Assumption. Diabetes. https://doi.org/10.2337/diab.46.11.1813
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.