Abstract

The contribution of the kidneys to postabsorptive endogenous glucose production is a matter of controversy. To assess whether this could relate to the use of various isotopical methods with different analytical performance capabilities, we measured glucose kinetics in 12 healthy subjects. Blood samples were taken from the femoral artery and the renal vein after 4 h of [6,6-2H2]glucose infusion (for gas chromatography [GC]/mass spectrometry [MS] analysis), and renal plasma flow was determined with paraaminohippurate. In addition, six subjects received uniformly labeled [13C]glucose (for GC/combustion/isotope ratio MS [IRMS]) and [3-3H]glucose (for counting of radioactive disintegrations). Arterial glucose concentrations (means ± SD) were 4.2 ± 0.1 mmol/l, and endogenous glucose production rates using [2H2]glucose were 2.2 ± 0.1 mg · kg–1 · min–1 or 818 ± 50 μmol/min. Dilution of [2H2]glucose across the kidney was 0.79 ± 1.32%, and renal glucose production (RGP) rates were 27 ± 72 μmol/min. In the six subjects receiving additional tracers, dilutions across the kidney were 2.83 ± 0.72 and 0.54 ± 1.20 (for [U-13C]glucose and [3-3H]glucose, respectively, the dilution with [U-13C] being higher than that with [2H2] (P = 0.007). Corresponding RGP values were 144 ± 39 and 43 ± 76 μmol/min for [U-13C] and [3-3H], respectively. In conclusion, we found that the highly sensitive [U-13C] GC/Combustion/IRMS technique showed consistent dilution of label across the kidney, whereas the less sensitive techniques gave some negative values and smaller RGP rates. Thus, depending on which technique is being used, a fivefold difference in calculated RGP values may be encountered. The methodological variability of our data suggests that extrapolation from regional renal measurements to the whole-body level should be perfumed with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diabetes.50.4.747

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 48

Metadata

Authors
Moller, N., Rizza, R. A., Ford, G. C., & Nair, K. S.
Venue
Diabetes
Published
2001-04-01
Volume
50
Issue
4
Pages
747-751
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W2099211459
Cited by
48
References
2
FWCI
3.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Postabsorptive Renal Glucose Metabolism in Humans With Multiple Glucose Tracers. https://app.cochat.ai/papers/10.2337/diabetes.50.4.747
The paper
Moller, N., Rizza, R. A., Ford, G. C., & Nair, K. S. (2001). Assessment of Postabsorptive Renal Glucose Metabolism in Humans With Multiple Glucose Tracers. Diabetes. https://doi.org/10.2337/diabetes.50.4.747

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.