Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 250

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Glucose Competence of the Hepatoportal Vein Sensor Requires the Presence of an Activated Glucagon-Like Peptide-1 Receptor

Burcelin, Rémy, Da Costa, Anabela, Drucker, Daniel, Thorens, Bernard·2001·Diabetes

Abstract

Activation of the hepatoportal glucose sensors by portal glucose infusion leads to increased glucose clearance and induction of hypoglycemia. Here, we investigated whether glucagon-like peptide-1 (GLP-1) could modulate the activity of these sensors. Mice were therefore infused with saline (S-mice) or glucose (P-mice) through the portal vein at a rate of 25 mg/kg · min. In P-mice, glucose clearance increased to 67.5 ± 3.7 mg/kg · min as compared with 24.1 ± 1.5 mg/kg · min in S-mice, and glycemia decreased from 5.0 ± 0.1 to 3.3 ± 0.1 mmol/l at the end of the 3-h infusion period. Coinfusion of GLP-1 with glucose into the portal vein at a rate of 5 pmol/kg · min (P–GLP-1 mice) did not increase the glucose clearance rate (57.4 ± 5.0 ml/kg · min) and hypoglycemia (3.8 ± 0.1 mmol/l) observed in P-mice. In contrast, coinfusion of glucose and the GLP-1 receptor antagonist exendin-(9-39) into the portal vein at a rate of 0.5 pmol/kg · min (P-Ex mice) reduced glucose clearance to 36.1 ± 2.6 ml/kg · min and transiently increased glycemia to 9.2 ± 0.3 mmol/l at 60 min of infusion before it returned to the fasting level (5.6 ± 0.3 mmol/l) at 3 h. When glucose and exendin-(9-39) were infused through the portal and femoral veins, respectively, glucose clearance increased to 70.0 ± 4.6 ml/kg · min and glycemia decreased to 3.1 ± 0.1 mmol/l, indicating that exendin-(9-39) has an effect only when infused into the portal vein. Finally, portal vein infusion of glucose in GLP-1 receptor−/− mice failed to increase the glucose clearance rate (26.7 ± 2.9 ml/kg · min). Glycemia increased to 8.5 ± 0.5 mmol/l at 60 min and remained elevated until the end of the glucose infusion (8.2 ± 0.4 mmol/l). Together, our data show that the GLP-1 receptor is part of the hepatoportal glucose sensor and that basal fasting levels of GLP-1 sufficiently activate the receptor to confer maximum glucose competence to the sensor. These data demonstrate an important extrapancreatic effect of GLP-1 in the control of glucose homeostasis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diabetes.50.8.1720

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 250

Metadata

Authors
Burcelin, R., Da Costa, A., Drucker, D., & Thorens, B.
Venue
Diabetes
Published
2001-08-01
Volume
50
Issue
8
Pages
1720-1728
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W2121497054
Cited by
250
References
2
FWCI
6.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Glucose Competence of the Hepatoportal Vein Sensor Requires the Presence of an Activated Glucagon-Like Peptide-1 Receptor. https://app.cochat.ai/papers/10.2337/diabetes.50.8.1720
The paper
Burcelin, R., Da Costa, A., Drucker, D., & Thorens, B. (2001). Glucose Competence of the Hepatoportal Vein Sensor Requires the Presence of an Activated Glucagon-Like Peptide-1 Receptor. Diabetes. https://doi.org/10.2337/diabetes.50.8.1720

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.