Reliability of Self-Monitoring of Blood Glucose by CSII Treated Patients With Type I Diabetes
The DOI matches its Crossref record.
Abstract
The reliability of patient-generated data from self-monitoring of blood glucose (SMBG) was studied in 14 patients with type I (insulin-dependent) diabetes mellitus treated by continuous subcutaneous insulin infusion (CSII) (7 women, 7 men). The reflectance meters (Glucometer I, Ames, Elkhart, IN) used by the patients were replaced for a period of 21 days by memory-reflectance meters; patients were unaware of the memory capacity of the new meters and were instructed to continue their practice of recording the meter readings in their logbook. This study compares the data recorded in the memory-reflectance meters with those reported in the logbook. The number of SMBG measurements was different in 11 patients (differences ranging from 2 to 66). Mean glycemia was similar (8.23 ± 0.36 mM in logbook vs. 8.49 ± 0.48 mM in memory-reflectance meters), but both the M value and mean amplitude of glycemic excursions (MAGE) index were lower when calculated from logbook data (38 ± 5 vs. 48 ± 7 mM, P < .05 and 6.91 ± 0.43 vs. 7.72 ± 0.52 mM, respectively; P < .05). Overreporting (addition of phantom values in logbook) and underreporting (omission of SMBG measurements from logbook) indexes were 19 ± 7 and 12 ± 3%, respectively. Precision (percent of identical values in logbook and in memory-reflectance meters at the corresponding time) was 77 ± 6.8%. The number of SMBG measurements recorded in the memory-reflectance meter was negatively correlated with glycosylated hemoglobin [HbA1c; (r = −.85, P < .001)], whereas overreporting was positively correlated with HbA1c (r = .76, P < .01). Unreliable patients (n = 5) had slightly but not significantly higher HbA1c levels than the others (n = 9; 7.4 ± 0.5 vs. 6.2 ± 0.2% NS). Sixty-five percent of the patients had recorded values in a manner that obscured hyper- or hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guerci, B., Drouin, P., Grangé, V, Bougnères, P., Fontaine, P., Kerlan, V, Passa, P., Thivolet, C., Vialettes, B., & Charbonnel, B. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70073-3 · Cited by 287
“Two studies have reported a relationship between the number of reagent strips used by the patients and the decrease of HbA1c in type 2 diabetic patients [10, 11], as has already been demonstrated in type 1 diabetic patients [21, 22].”
BackgroundSelf-citationMonitoring blood glucose control in diabetes mellitus: a systematic review.
Coster, Gulliford, Seed, Powrie, & Swaminathan (2000) · Health Technology Assessment · doi:10.3310/hta4120 · Cited by 245
Wysocki, T., Harris, M. A., Buckloh, L. M., Mertlich, D., Lochrie, A. S., Taylor, A., Sadler, M., & White, N. H. (2008) · Behavior Therapy · doi:10.1016/j.beth.2007.04.001 · Cited by 197
Davidson, M. B., Castellanos, M., Kain, D., & Duran, P. (2005) · The American Journal of Medicine · doi:10.1016/j.amjmed.2004.12.006 · Cited by 178
Evolution of analytical performance in portable glucose meters in the last decade
Böhme, P., Floriot, M., Sirveaux, M.-A., Durain, D., Ziegler, O., Drouin, P., & Guerci, B. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1170 · Cited by 51
Self-citation
Metadata
- Authors
- Ziegler, O., Kolopp, M., Isabelle, G., Genton, P., Debry, G., & Drouin, P.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1989-03-01
- Volume
- 12
- Issue
- 3
- Pages
- 184-188
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2066912544
- Cited by
- 55
- References
- 0
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.