The DOI matches its Crossref record.
Reduction in Severe Hypoglycemia With Long-Term Continuous Subcutaneous Insulin Infusion in Type I Diabetes
Abstract
Objective To compare the incidence of severe hypoglycemia in patients crossed over from multiple daily injections (MDIs) of insulin to continuous subcutaneous insulin infusion (CSII). Research design and methods From a population of 225 patients using CSII, all patients who met the following selection criteria were included in the present study: 1) a minimum of 12 months on intensive therapy with MDIs before switching to CSII, and 2) a minimum of 12 months on CSII after crossover. Glycemic control and adverse event rates for the 1-year MDI control period were compared with those for the CSII therapy period. Results The incidence of severe hypoglycemia during MDI therapy declined from 138 to 22 events per 100 patient-years during the 1st year of CSII (P or = 8.0%, the change to CSII was associated with a significant reduction in HbA1c from baseline to year 1 (8.9 +/- 0.8 vs. 8.1 +/- 1.0%, P = 0.0004). The difference in diabetic ketoacidosis rates between the MDI year (14.6 events per 100 patient-years) and the CSII period (7.2 events per 100 patient-years) was not statistically significant. Conclusions CSII therapy was associated with a marked and sustained reduction in the rate of severe hypoglycemia without adversely affecting the level of glycemic control attained during MDI therapy. The more reproducible and flexible insulin delivery afforded by CSII was considered to be the major factor contributing to the improvement in severe hypoglycemia rates.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Potential advantages of insulin pump therapy compared with MDI include improved glycemic control, reduced rate of severe hypoglycemia, greater flexibility, and higher quality of life.2–6”
From Impact of government-funded insulin pump programs on insulin pump use in Canada: a cross-sectional study using the National Diabetes Repository (2021) · cites this paper as [2]
In the citing paper
“insulin pump therapy may improve glycemic control”
From Impact of government-funded insulin pump programs on insulin pump use in Canada: a cross-sectional study using the National Diabetes Repository (2021) · cites this paper as [2]
In the citing paper
“is associated with greater quality of life.2–6”
From Impact of government-funded insulin pump programs on insulin pump use in Canada: a cross-sectional study using the National Diabetes Repository (2021) · cites this paper as [2]
In the citing paper
“reduces the rate of severe hypoglycemia”
From Impact of government-funded insulin pump programs on insulin pump use in Canada: a cross-sectional study using the National Diabetes Repository (2021) · cites this paper as [2]
Citations
Cites
Still being checked.
Cited by
Sorted by citations
Items 201–258 of 258
Insulin, glucagon, and hypoglycemic drugs
Krans, H. M. J. (2003) · Side effects of drugs annual · doi:10.1016/s0378-6080(03)80049-1 · Cited by 1
Pector, E. A., Schutta, M. H., & Seshadri, P. (2005) · Cited by 1
Joseph, J. I. (2016) · doi:10.3109/9780849379581-41 · Cited by 1
Insulin Pump Therapy in the Management of Diabetes
Plodkowski, R. A., & Edelman, S. V. (2003) · Humana Press eBooks · doi:10.1007/978-1-59259-375-0_13 · Cited by 1
Open- and Closed-Loop Insulin Delivery Systems and Glucose Sensors
Pickup, J. C. (2003) · Humana Press eBooks · doi:10.1007/978-1-59259-310-1_12
The Advantages and Disadvantages of Insulin Pump Therapy
Rodgers, J. (2008) · Wiley eBooks · doi:10.1002/9780470988053.ch2
Berger, M., & Jörgens, V. (2001) · Springer eBooks · doi:10.1007/978-3-642-97548-6_13
Autumn 2005 Meeting of the Association of British Clinical Diabetologists
Amiel, S. A., & Kilvert, A. (2006) · Practical Diabetes · doi:10.1002/pdi.906
Is Multiple Injection Therapy the Treatment of Choice in Type 1 Diabetes?
Janssen, M. M. J., & Heine, R. J. (2001) · Wiley eBooks · doi:10.1002/9780470757109.ch12
Insulin Pumps in Babies, Children and Teenagers
Rodgers, J. (2008) · Wiley eBooks · doi:10.1002/9780470988053.ch13
Clinical studies of glucose variability and hypoglycemia in adult patients with type 1 diabetes
Bragd, J. (2011) · Figshare
Álvarez, M. G. (2012) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Gregory, J. M. (2011) · Humana Press eBooks · doi:10.1007/978-1-60327-256-8_13
The Patient With Type 1 Diabetes and Hypoglycemia
Kudva, Y. C., Khoo, T.-K., & Tebben, P. J. (2007) · Humana Press eBooks · doi:10.1007/978-1-59745-008-9_17
Subcutaneous insulin infusion in type 1 diabetes mellitus
Hoogma, R. P. L. M. (2003) · UvA-DARE (University of Amsterdam)
Gastrointestinal upset following improvement of HbA1con initiation of pump therapy
Partridge, H., & Kerr, D. E. (2009) · Practical Diabetes · doi:10.1002/pdi.1320
Response to Kirkman and Juneja and Lorber
Kitabchi, A. E., & for the writing team (2001) · Diabetes Care · doi:10.2337/diacare.24.11.2010
Insulin pump therapy revisited in pioneer countries
Hanås, R. (2005) · Practical Diabetes · doi:10.1002/pdi.773
Criterios y fundamentos para la utilización de la bomba de insulina
Marí-Sanchis, A., Palacios, S. S., & Martín, J. E. S. (2009) · FMC - Formación Médica Continuada en Atención Primaria · doi:10.1016/s1134-2072(09)70478-5
Instabilité glycémique et anticorps anti-insuline
Renard, É., Radermecker, R. P., & Scheen, A. J. (2008) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(08)74901-0
Aspectos clínicos y diagnósticos de la diabetes infantil
Bouhours‐Nouet, N., & Coutant, R. (2011) · EMC - Pediatría · doi:10.1016/s1245-1789(11)71180-5
Pompes à insuline externes et implantables dans le diabète de type 1 : bénéfices et perspectives
Hanaire, H. P., Melki, V., & Puech, N. (2012) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(12)70466-2
Reis, J. S., Lamounier, R. N., Menezes, P. A. F. C., Calsolari, M. R., & Purisch, S. (2008) · Arquivos Brasileiros de Endocrinologia & Metabologia · doi:10.1590/s0004-27302008000400017
Morris, D. (2015) · Independent Nurse · doi:10.12968/indn.2015.15.19
Insulinpumpentherapie bei Kindern, Jugendlichen und Erwachsenen
Stadler, M., Zlamal-Fortunat, S., Schütz-Fuhrmann, I., Rami-Merhar, B. M., Fröhlich-Reiterer, E. E., Hofer, S. E., Mader, J. K., Resl, M., Kautzky‐Willer, A., Weitgasser, R., et al. (2016) · Wiener klinische Wochenschrift · doi:10.1007/s00508-016-0966-0
Bringer, J., Costalat, G., Jaffiol, C., & Renard, É. (2003) · Bulletin de l Académie Nationale de Médecine · doi:10.1016/s0001-4079(19)33910-x
Treatment Patterns in Youth with Diabetes
Chiu, H., & Pihoker, C. (2008) · CRC Press eBooks · doi:10.3109/9781420047981-20
Hypoglycemia in type 1 diabetes:The need for a new approach
Amiel, S. A. (2007) · Research Portal (King's College London)
Insulin pumps and pancreas transplantation for unstable and brittle diabetes
Pickup, J. C. (2004) · CRC Press eBooks · doi:10.3109/9780203640562-14
Chronic unstable diabetes and hypoglycaemia
Heller, S. R. (2004) · CRC Press eBooks · doi:10.3109/9780203640562-8
Akhmetzyanova, T. N., Valeeva, F. V., Бареева, Л. Т., Газизова, Г. Р., & Abakumov, A. A. (2011) · CyberLeninK (CyberLeninka)
Cohen, O. (2008) · Series in maternal-fetal medicine · doi:10.3109/9781439802007.030
Ahmad, H. F. (2012) · SMARTech Repository (Georgia Institute of Technology)
Çetinkalp, Ş., Erdoğan, M., Karadeniz, M., özbey, Y., Yılmaz, C., Tüzün, M., & Kabalak, T. (2007) · DOAJ (DOAJ: Directory of Open Access Journals)
Haase, M., Kahle, M., Janert, M., Meier, J. J., & Nauck, M. A. (2017) · Diabetes Obesity and Metabolism · doi:10.1111/dom.12868
Sistrunk, J. W., & Zimmerman, B. R. (2002) · Humana Press eBooks · doi:10.1007/978-1-59259-277-7_16
Bin-Abbas, B. S., Al-Fares, A., Sakati, N., & Al-Ashwal, A. A. (2006) · Current Pediatric Research
Zabeen, B., Nahar, J., Islam, N., Azad, K., & Donaghue, K. C. (2020) · Dubai Diabetes and Endocrinology Journal · doi:10.1159/000511241
Placement of insulin pump by telemedicine
Foglia, A. (2020) · The Journal of AMD · doi:10.36171/jamd20.23.4.6
糖尿病を発症した経腸栄養療法施行中の重症心身障害児に持続皮下インスリン注入療法(CSII)を用い良好な血糖コントロールが得られた1例
洋平, 小., 安子, 内., 三浦, 順., 慶香, 柳., 宏, 佐., & 岩本安彦 (2008) · Tōnyōbyō/Tounyoubyou · doi:10.11213/tonyobyo.51.9
Therapy of Type 1 Diabetes Mellitus
Omura, E., & Peters, A. L. (2016) · Springer eBooks · doi:10.1007/978-3-319-20797-1_43-1
Brado, M., Bierhaus, A., Clemens, A., Dugi, K. A., Haass, M., Hammes, H., Herbay, A. V., Hofmann, M. A., Isermann, B., Kassessinoff, T. A., et al. (2001) · Springer eBooks · doi:10.1007/978-3-642-56784-1_16
Meyer, C., Wittlin, S. D., & Gerich, J. E. (2004) · Springer eBooks · doi:10.1007/978-1-4757-6260-0_16
(2006) · Springer eBooks · doi:10.1007/3-540-26602-x_12
Therapy of Type 1 Diabetes Mellitus
Omura, E., Cohan, P., & Peters, A. L. (2017) · Springer eBooks · doi:10.1007/978-3-319-18741-9_43
Insulin, glucagon, and hypoglycemic drugs
Krans, H. M. J. (1997) · Side effects of drugs annual · doi:10.1016/s0378-6080(05)80404-0
Isermann, B., Klevesath, M. S., & Nawroth, P. (1999) · Springer eBooks · doi:10.1007/978-3-642-58588-3_7
Aspectos clínicos y diagnósticos de la diabetes infantil
Louvigné, M., Decrequy, A., Donzeau, A., Bouhours‐Nouet, N., & Coutant, R. (2018) · EMC - Pediatría · doi:10.1016/s1245-1789(17)88072-0 · Cited by 1
Joseph, J. I. (2007) · CRC Press eBooks · doi:10.3109/9780849379581-39
ESTIMATION OF TYPE 1 DIABETES COMPENSATION BY RESULTS OF GLUCOSE LONG MONITORING
Makhlina, E. (2008) · Health and Ecology Issues · doi:10.51523/2708-6011.2008-5-3-11
Chappel, E. (2024) · Encyclopedia · doi:10.3390/encyclopedia4020052
Berk, B. (2024) · Journal of Drug Delivery and Therapeutics · doi:10.22270/jddt.v14i11.6934
History of the development of insulin pump therapy technology
Kazaryan, P. A., Golosov, K. A., Poluboyarinova, I. V., & Fadeev, V. V. (2026) · Terapevticheskii arkhiv · doi:10.26442/00403660.2026.01.203508
Clemens, A., Wahl, P. M., Klöppel, G., & Nawroth, P. (1999) · Springer eBooks · doi:10.1007/978-3-642-58588-3_3
Metadata
- Authors
- Bode, B. W., Steed, R. D., & Davidson, P. C.
- Affiliations
- Atlanta Diabetes Associates (US)
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1996-04-01
- Volume
- 19
- Issue
- 4
- Pages
- 324-327
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W1989943003
- Cited by
- 257
- References
- 0
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 1 · 2020: 7 · 2019: 2 · 2018: 6 · 2017: 7 · 2016: 5 · 2015: 5 · 2014: 8 · 2013: 6 · 2012: 9
- FWCI
- 2.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- severe hypoglycemia, insulin pump therapy, type 1 diabetes, multiple daily insulin injections, insulin delivery, glycemic control, HbA1c, diabetic ketoacidosis, intensive insulin therapy
- MeSH terms
- Adult, Algorithms, Diabetes Mellitus, Type 1, Female, Follow-Up Studies, Glycated Hemoglobin, Humans, Hypoglycemia, Insulin, Insulin Infusion Systems, Male, Time Factors, Blood Glucose Self-Monitoring, Incidence, Diabetic Ketoacidosis, Patient Selection, Cross-Over Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review