Multicenter Evaluation of the Micral-Test II Test Strip, an Immunologic Rapid Test for the Detection of Microalbuminuria
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To assess the performance of the Micral-Test II immunologic test strip for the detection of microalbuminuria, a multicenter evaluation in eight European study sites was performed. RESEARCH DESIGN AND METHODS: Using both the Micral-Test II test strip and the routine method for the determination of albumin concentration, we investigated 2,228 urine samples from diabetic patients. Additionally, interperson variability, color stability, and possible interfering factors (temperature, pH, leucocyturia, erythrocyturia, and drugs) were tested. RESULTS: For a cutoff concentration of 20 mg/l with respect to the routine methods, a sensitivity of 96.7% and a specificity of 71% were calculated for the Micral-Test II test strip. The negative predictive value was 0.95, and the positive predictive value was 0.78, with a prevalence of positive samples (laboratory method) of 52%. The interperson variability of color interpretation showed 93% concordant readings. The interference study showed an influence of oxytetracycline, leading to higher readings. There was no interference from pH. A sample temperature of <10 degrees C led to lower readings. In the case of samples with massive leucocyturia and erythrocyturia that may delete the chromatographic process, waiting an additional 1-2 min is needed before reading. CONCLUSIONS: The results of the multicenter evaluation show that the Micral-Test II test strip permits an immediate and reliable semiquantitative determination of low albumin concentrations in urine samples with an almost user-independent color interpretation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diabetic nephropathy: diagnosis, prevention, and treatment
Gross, J. L., de Azevedo, M. J., Silveiro, S. P., Canani, L. H., Caramori, M. L., & Zelmanovitz, T. (2005) · Diabetes Care · doi:10.2337/diacare.28.1.164 · Cited by 1,839
European Urinalysis Guidelines
Kouri, T., Fogazzi, G., Gant, V., Hallander, H., Hofmann, W., & Guder, W. G. (2000) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2000.12056993 · Cited by 384
Self-citationMicroalbuminuria, blood pressure and diabetic renal disease: origin and development of ideas
Mogensen, C. E. (1999) · Diabetologia · doi:10.1007/s001250051151 · Cited by 274
Self-citationEvaluation of tests for microalbuminuria screening in patients with diabetes
Incerti, J., Zelmanovitz, T., Camargo, J. L., Gross, J. L., & de Azevedo, M. J. (2005) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfi074 · Cited by 93
“[12], in a large multicentric study, observed a sensitivity of 96.”
InfluentialCost-effectiveness of two screening programs for microalbuminuria in type 2 diabetes
Lepore, G., Maglio, M. L., Nosari, I., Dodesini, A. R., & Trevisan, R. (2002) · Diabetes Care · doi:10.2337/diacare.25.11.2103 · Cited by 26
Metadata
- Authors
- Mogensen, C. E., Viberti, G. C., Peheim, E., Kutter, D., Hasslacher, C., Hofmann, W., Renner, R., Bojestig, M., Poulsen, P. L., Scott, G., Thoma, J., Kuefer, J., Nilsson, B., Gambke, B., Mueller, P., Steinbiss, J., & Willamowski, K.-D.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1997-11-01
- Volume
- 20
- Issue
- 11
- Pages
- 1642-1646
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2062904703
- Cited by
- 68
- References
- 0
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multicenter Evaluation of the Micral-Test II Test Strip, an Immunologic Rapid Test for the Detection of Microalbuminuria. https://app.cochat.ai/papers/10.2337/diacare.20.11.1642
- The paper
- Mogensen, C. E., Viberti, G. C., Peheim, E., Kutter, D., Hasslacher, C., Hofmann, W., Renner, R., Bojestig, M., Poulsen, P. L., Scott, G., Thoma, J., Kuefer, J., Nilsson, B., Gambke, B., Mueller, P., Steinbiss, J., & Willamowski, K.-D. (1997). Multicenter Evaluation of the Micral-Test II Test Strip, an Immunologic Rapid Test for the Detection of Microalbuminuria. Diabetes Care. https://doi.org/10.2337/diacare.20.11.1642
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.