CoChat

The Use of Biothesiometry to Detect Neuropathy in Children and Adolescents With IDDM

Davis, E A, Jones, T W, Walsh, P, Byrne, G C · 1997 · Diabetes Care
Cited by 51

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To develop clinically useful reference ranges for vibration perception thresholds (VPTs), using biothesiometry in children and adolescents and to assess the reliability of the technique to identify subclinical neuropathy in subjects with IDDM at this age and to examine a large population-based sample of pediatric patients. RESEARCH DESIGN AND METHODS: VPTs were measured using a handheld biothesiometer at the medial malleolus and hallux in 232 nondiabetic children and adolescents aged 7–18 years (12.9 ± 4.2 years) and a population-based sample of 307 young IDDM patients (13.3 ± 4.6 years of age). The mean of three readings at each site was correlated with height, pubertal status, and age for all subjects and, in addition for the IDDM sample, with the duration of IDDM, ambient blood glucose, and mean HbA1c from diagnosis. Those IDDM subjects found to have elevated VPTs (> 97th percentile), and a control group of patients with IDDM underwent nerve conduction studies to determine the sensitivity and specificity of biothesiometry to detect abnormal neural function in children. Interoperator reliability was assessed in a separate trial in which two operators measured VPTs independently in the same 11 children. RESULTS: In the nondiabetic control subjects, height demonstrated the best correlation with VPT measures, and a reference range was thus established with percentile charts, using mean VPT and height. VPTs were higher in the diabetic sample, compared with the nondiabetic sample (P < 0.05). Of the children, 28 (9.1%) had VPT values > 97th percentile developed from studies of the nondiabetic subjects; of these, 11 were younger than 11 years and 8 were prepubertal. Nerve conduction studies confirmed reduced conduction velocity and prolonged distal latencies in those with abnormal VPTs, compared with normal control subjects and IDDM patients with normal VPTs. Sensitivity of biothesiometry to reflect abnormal nerve function was estimated as 82% and specificity as 75% at this age. Interoperator variation was small (7.25% of total variance). CONCLUSIONS: Biothesiometry is a useful noninvasive tool for the detection of subclinical neuropathy in children and adolescents. The use of height-related reference ranges may make screening for neuropathy more feasible in younger patients and allow large-scale longitudiral analysis of its development.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.20.9.1448

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 51

Metadata

Authors
Davis, E. A., Jones, T. W., Walsh, P., & Byrne, G. C.
Venue
Diabetes Care
Published
1997-09-01
Volume
20
Issue
9
Pages
1448-1453
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2102476609
Cited by
51
References
0
FWCI
0.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Use of Biothesiometry to Detect Neuropathy in Children and Adolescents With IDDM. https://app.cochat.ai/papers/10.2337/diacare.20.9.1448
The paper
Davis, E. A., Jones, T. W., Walsh, P., & Byrne, G. C. (1997). The Use of Biothesiometry to Detect Neuropathy in Children and Adolescents With IDDM. Diabetes Care. https://doi.org/10.2337/diacare.20.9.1448

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.