CoChat

Insulin Secretion in Normal Glucose-Tolerant Relatives of Type 2 Diabetic Subjects: Assessments using hyperglycemic glucose clamps and oral glucose tolerance tests

van Haeften, Timon W, Dubbeldam, Suzanne, Zonderland, Maria L, Erkelens, D Willem · 1998 · Diabetes Care
Cited by 95

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To assess insulin secretion in normal glucose-tolerant Caucasian first-degree relatives of type 2 diabetes subjects and in matched normal glucose-tolerant control subjects and to compare insulin secretion as assessed using a hyperglycemic glucose clamp with insulin secretion as assessed using an oral glucose tolerance test (OGTT). RESEARCH DESIGN AND METHODS: Twenty-one first-degree relatives of type 2 diabetic subjects and 21 control subjects without a family history of type 2 diabetes, who were matched for sex, age, BM1, waist-to-hip ratio, and aerobic capacity, underwent a hyperglycemic glucose clamp (10 mmol/1, 180 min). An OGTT (75 g glucose in 300 ml water) was also performed. RESULTS: First-phase insulin release (plasma insulin, 0–10 min) was not different (multiple analysis of variance [MANOVA]: F = 2.63, P = 0.11). Second-phase insulin release was lower (MANOVA: F = 4.18, P = 0.047). Separate analyses of variance showed decreased plasma insulin levels from 120 min onward (all P < 0.05), decreasing to geometric mean (95% CI) levels of 330 (270–402) and 462 (366–582) pmol/1 at 180 min in relatives and control subjects, respectively. The insulin sensitivity index (ISI) as assessed using a hyperglycemic clamp was not different between the two groups. Mean ± SE ISI during the 3rd hour was 27.5 ± 2.2 and 30.5 ± 3.0 μg · kg−1 · min−1 · pmol−1 · l−1 in relatives and control subjects, respectively (P > 0.20). At 90 min after the OGTT, log plasma insulin levels correlated significantly with secondphase insulin release as assessed using the hyperglycemic glucose clamp. CONCLUSIONS: Normal glucose-tolerant first-degree relatives of type 2 diabetic subjects have a decreased second-phase insulin release, compared with matched control subjects. After an OGTT, 90-min values of log plasma insulin and 90-min values of the ratio of log plasma insulin to blood glucose may be good indicators of insulin secretory properties in normal glucose-tolerant family members of type 2 diabetic subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.21.2.278

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 95

Metadata

Authors
van Haeften, T. W., Dubbeldam, S., Zonderland, M. L., & Erkelens, D. W.
Venue
Diabetes Care
Published
1998-02-01
Volume
21
Issue
2
Pages
278-282
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2085392333
Cited by
95
References
0
FWCI
6.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Insulin Secretion in Normal Glucose-Tolerant Relatives of Type 2 Diabetic Subjects: Assessments using hyperglycemic glucose clamps and oral glucose tolerance tests. https://app.cochat.ai/papers/10.2337/diacare.21.2.278
The paper
van Haeften, T. W., Dubbeldam, S., Zonderland, M. L., & Erkelens, D. W. (1998). Insulin Secretion in Normal Glucose-Tolerant Relatives of Type 2 Diabetic Subjects: Assessments using hyperglycemic glucose clamps and oral glucose tolerance tests. Diabetes Care. https://doi.org/10.2337/diacare.21.2.278

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.