CoChat

Gastric Emptying Delay and Gastric Electrical Derangement in IDDM

Cucchiara, Salvatore, Franzese, Adriana, Salvia, Gennaro, Alfonsi, Lucia, Iula, Vita D, Montisci, Antonella, Moreira, Flavio L · 1998 · Diabetes Care
Cited by 81

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Patients with diabetes can develop gastrointestinal motor complications; however, prevalence of gut dysmotility in children with diabetes is poorly understood. We measured gastric emptying time and gastric electrical activity in children with IDDM; presence of dyspeptic symptoms was also assessed. RESEARCH DESIGN AND METHODS: Gastric emptying time and gastric electrical activity were measured by ultrasonography and electrogastrography (EGG), respectively, in 40 consecutive IDDM children (median age: 9 years [6–14]) without autonomic neuropathy; 15 healthy children (median age: 7 years [4–15]) served as control subjects. The EGG variables studied were percent of electrical dysrhythmias (bradygastria or 0.5−2.0 cpm, tachygastria or 4.0–9.0 cpm; normal rhythm is 2.0–4.0 cpm) and fed-to-fasting ratio of the dominant EGG power. Blood glucose level in the fasting state and 180 min after feeding and HbA1C concentration were also measured. Data are given as median (ranges) and means ± SD. Statistical analysis was performed using the parametric t test and the nonparametric signed-rank tests, with P < 0.05 considered significant. RESULTS: Gastric emptying time was delayed in 26 patients (group A), whereas in 14 patients (group B), it was in the same range as control values; group A patients significantly differed from group B for increased prevalence of gastric electrical dysrhythmias (P < 0.01) and for a lower fed-to-fasting ratio of the dominant EGG power (P < 0.01). Group B patients did not differ from control subjects for the EGG variables measured. Diabetic children with gastroparesis had significantly higher levels of both HbA1C and blood glucose measured 180 min after feeding than those with normal gastric emptying time (P < 0.05); there was a significant correlation between levels of HbA1C and degree of gastric emptying delay, whereas a significant inverse correlation between gastric emptying time and fed-to-fasting ratio of the dominant EGG power was found both in patients and control subjects. CONCLUSIONS: Delay of gastric emptying time and gastric electrical abnormalities are found in a high proportion of children with diabetes and can contribute to poor glycemic control, most likely by causing a mismatch between the onset of insulin action and the delivery of nutrients into the small intestine. Diabetic children with unexplained poor glycemic control should be investigated for abnormalities in gastric motility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.21.3.438

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Cucchiara, S., Franzese, A., Salvia, G., Alfonsi, L., Iula, V. D., Montisci, A., & Moreira, F. L.
Venue
Diabetes Care
Published
1998-03-01
Volume
21
Issue
3
Pages
438-443
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2031276263
Cited by
81
References
1
FWCI
5.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.