Fasting Plasma Glucose Is a Useful Test for the Detection of Gestational Diabetes
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate fasting plasma glucose as a screening test for states of gestational diabetes. RESEARCH DESIGN AND METHODS: Baseline data of a cohort conducted in general prenatal care units in Brazil, enrolling 5,579 women aged ≥ 20 years with gestational ages of 24–28 weeks at the time of testing and no previous diagnosis of diabetes. A standardized 2-h 75-g oral glucose tolerance test was performed in 5,010 women. Gestational diabetes and its subcategories—diabetes and impaired glucose tolerance—were defined according to the 1994 World Health Organization panel recommendations. We evaluated screening properties of calculated sensitivity and specificity for fasting plasma glucose with receiver operator characteristic curves. RESULTS: For detection of the subcategory diabetes, a fasting plasma glucose of 89 mg/dl jointly maximizes sensitivity (88%) and specificity (78%), identifying 22% of the women as test-positive. For detection of impaired glucose tolerance, a value of 85 mg/dl jointly maximizes sensitivity and specificity (68%), identifying as test-positive 35% of the women. Lowering the cut point to 81 mg/dl increases sensitivity to 81%, but decreases specificity to 54%, labeling as test-positive 49% of the women. CONCLUSIONS: Fasting plasma glucose is a useful test for the screening of both subcategories of gestational diabetes, a threshold of 85 mg/dl being an acceptable option. Effective screening for the subcategory diabetes can be achieved using a cut point of 89 mg/dl. If greater emphasis is placed on the detection of impaired glucose tolerance, a lower value, 81 mg/dl, may be needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Criteria for screening tests for gestational diabetes
Carpenter, M. W., & Coustan, D. R. (1982) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(82)90349-0 · Cited by 1,924
Screening criteria for high-risk gestational diabetic patients
O'Sullivan, J. B., Mahan, C. M., Charles, D., & Dandrow, R. V. (1973) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(16)33833-9 · Cited by 478 · cited 4×
“In their original studies, the 1-h postload whole blood glucose level of 130 mg/dl (~150 mg/dl in plasma) reached a sensitivity of 79% and a specificity of 87% compared with the 3-h 100-g OGTT (4).”
BackgroundMethodResultInfluential
Cited by
(2007) · Endocrine Practice · doi:10.4158/ep.13.s1.1 · Cited by 699
Screening for gestational diabetes; past, present and future
Hanna, F. W. F., & Peters, J. R. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.2002.00684.x · Cited by 160
“Two recent studies (Reichelt et al. 1998 [35] and Peruchini et al. 1999 [6]) have evaluated the sensitivity and specificity of fasting plasma glucose against more standard methods for screening (see Table 5 for details).”
MethodGestational diabetes mellitus: An update on the current international diagnostic criteria
Agarwal, M. M. (2015) · World Journal of Diabetes · doi:10.4239/wjd.v6.i6.782 · Cited by 128
Donovan, L., Hartling, L., Muise, M., Guthrie, A., Vandermeer, B., & Dryden, D. M. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-2-201307160-00657 · Cited by 125
Cho, H. Y., Jung, I., & Kim, S. J. (2016) · Medicine · doi:10.1097/md.0000000000004712 · Cited by 23
Metadata
- Authors
- Reichelt, A. J., Spichler, E. R., Branchtein, L., Nucci, L. B., Franco, L. J., Schmidt, M. I., & Brazilian Study of Gestational Diabetes (EBDG) Working Group
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1998-08-01
- Volume
- 21
- Issue
- 8
- Pages
- 1246-1249
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2059131767
- Cited by
- 115
- References
- 2
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.