CoChat

Day-to-day variability of fasting plasma glucose in newly diagnosed type 2 diabetic subjects.

Ollerton, R L, Playle, R, Ahmed, K, Dunstan, F D, Luzio, S D, Owens, D R · 1999 · Diabetes Care
Cited by 90

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To determine the day-to-day intraindividual variability of fasting plasma glucose (FPG) in newly diagnosed Caucasian type 2 diabetic subjects. RESEARCH DESIGN AND METHODS: A total of 193 newly diagnosed, previously untreated, Caucasian type 2 diabetic subjects (135 men, 58 women) had FPG measured on two consecutive days (FPG1, FPG2). Ethical approval and subjects' full informed consent were obtained. Subjects fasted for 12 h before each study day and rested for at least 30 min before blood was taken. Plasma glucose was analyzed by a glucose oxidase method with intra- and interassay coefficients of variation (CVs) < 2%. Variability of FPG was assessed by comparison of percentage differences (PDs): PD = 100 (FPG2 - FPG1)/FPG1, with averaged FPG (FPGaver = [FPG1 + FPG2]/2). Biological and analytical variability were determined by use of SD2total = SD2biological + SD2analytical, where SD2analytical approximately equal to 2 x (CVglucose measurement)2. Given normally distributed data with zero mean, 95% of daily percentage differences will be expected to fall within a range of +/- 2 SDtotal. RESULTS: Subjects were age 54 +/- 10 years (mean +/- SD) and had BMI of 29.3 +/- 5.3 kg/m2. FPG values for both days were 12.2 +/- 3.4 mmol/l (FPG1) and 12.1 +/- 3.3 mmol/l (FPG2), with a mean paired difference (95% CI) of 0.1 (0.0 to 0.3) mmol/l. The variance of these differences increased with increasing FPGaver. The PDs did not exhibit this effect and were normally distributed (mean -0.6% [-1.7 to 0.4]; SD 7.4% [6.8 to 8.3]), giving a 95% variability (2 SD) of 14.8%. Biological variability (2 SDbiological) was 13.7%. No significant difference in PD was found between men and women (mean difference 1.3% [-1.0 to 3.6]; SDmale 7.4%, SDfemale 7.3%; P = 0.62). CONCLUSIONS: A total of 95% of the FPG values for this group of newly diagnosed type 2 diabetic subjects varied within approximately +/- 15% on a daily basis, with approximately 14% caused by biological variability. As these results are expressed in percentage terms, subjects in the group with higher FPG values are likely to experience larger changes in FPG values measured from day to day. This variability should be considered when using FPG for the diagnosis and/or monitoring of response to treatment in patients with type 2 diabetes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.22.3.394

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 90

Metadata

Authors
Ollerton, R. L., Playle, R., Ahmed, K., Dunstan, F. D., Luzio, S. D., & Owens, D. R.
Venue
Diabetes Care
Published
1999-03-01
Volume
22
Issue
3
Pages
394-398
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2080373048
Cited by
90
References
0
FWCI
1.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Day-to-day variability of fasting plasma glucose in newly diagnosed type 2 diabetic subjects. https://app.cochat.ai/papers/10.2337/diacare.22.3.394
The paper
Ollerton, R. L., Playle, R., Ahmed, K., Dunstan, F. D., Luzio, S. D., & Owens, D. R. (1999). Day-to-day variability of fasting plasma glucose in newly diagnosed type 2 diabetic subjects. Diabetes Care. https://doi.org/10.2337/diacare.22.3.394

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.