How valid is fasting plasma glucose as a parameter of glycemic control in non-insulin-using patients with type 2 diabetes?
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To assess the value of fasting blood glucose as a parameter for glycemic control in type 2 diabetic patients not using insulin. RESEARCH DESIGN AND METHODS: In 1,020 type 2 diabetic patients treated with diet or oral hypoglycemic agents (OHAs), measurements of fasting plasma glucose (FPG) and HbA1c were taken. In 617 patients, the measurement could be repeated after 3 months. Cross-sectional correlation coefficients were calculated for the association between HbA1c and FPG. Receiver-operating characteristic (ROC)-curve analyses were applied to examine the performance of FPG as a diagnostic test for HbA1c. Longitudinally, the change in FPG was compared with the change in HbA1c, with both correlation measures and ROC curve analyses. RESULTS: Correlation coefficients between HbA1c and FPG and between FPG change and HbA1c change were 0.77 and 0.65, respectively. ROC curve analysis showed that HbA1c is difficult to predict from FPG values: 66% of the patients with good HbA1c (< 7.0%) were identified as such by FPG values < 7.8 mmol/l. As a test for HbA1c change, FPG change performed moderately: the highest combined values of sensitivity and specificity (87.7 and 57%, respectively) were reached at a cutoff point of zero in the range of FPG change values. CONCLUSIONS: FPG and HbA1c values that do not correspond are not rare in type 2 diabetic patients on diet or OHA treatment. HbA1c is difficult to predict from FPG values, and even more difficult is the prediction of HbA1c changes from FPG changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diabetes control and complications: the role of glycated haemoglobin, 25 years on
Jeffcoate, S. L. (2004) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.01065.x · Cited by 252
Tackling Hyperglycemia: A More Comprehensive Approach
Del Prato, S. (2006) · Endocrine Practice · doi:10.4158/ep.12.s1.63 · Cited by 160
Hay, L. C., Wilmshurst, E. G., & Fulcher, G. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503763816427 · Cited by 143
Morning Hyperglycemic Excursions
Monnier, L., Colette, C., Rabasa-Lhoret, R., Lapinski, H., Caubel, C., Avignon, A., & Boniface, H. (2002) · Diabetes Care · doi:10.2337/diacare.25.4.737 · Cited by 96
Murata, G. H., Hoffman, R. M., Wendel, C. S., Shah, J. H., & Duckworth, W. C. (2004) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200406000-00004 · Cited by 27
Metadata
- Authors
- Bouma, M., Dekker, J. H., de Sonnaville, J. J., van der Does, F. E., de Vries, H., Kriegsman, D. M., Kostense, P. J., Heine, R. J., & van Eijk, J. T.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1999-06-01
- Volume
- 22
- Issue
- 6
- Pages
- 904-907
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2066336559
- Cited by
- 77
- References
- 0
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How valid is fasting plasma glucose as a parameter of glycemic control in non-insulin-using patients with type 2 diabetes? https://app.cochat.ai/papers/10.2337/diacare.22.6.904
- The paper
- Bouma, M., Dekker, J. H., de Sonnaville, J. J., van der Does, F. E., de Vries, H., Kriegsman, D. M., Kostense, P. J., Heine, R. J., & van Eijk, J. T. (1999). How valid is fasting plasma glucose as a parameter of glycemic control in non-insulin-using patients with type 2 diabetes? Diabetes Care. https://doi.org/10.2337/diacare.22.6.904
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.