Differences in the performance of commercially available 10-g monofilaments.
The DOI matches its Crossref record.
Abstract
OBJECTIVE: This independent study was designed to determine the accuracy of 10-g monofilaments manufactured and supplied by popular commercial companies. RESEARCH DESIGN AND METHODS: A total of 160 new 10-g monofilaments (30 Semmes-Weinstein monofilaments [North Coast Medical], 30 Timesco/Sensory Testing Systems monofilaments, 50 Owen Mumford Neuropens, and 50 Bailey Instruments monofilaments) were tested using a calibrated load cell. Each monofilament was subjected to 10 mechanical bucklings of 10 mm while the load cell detected the maximum buckling force. Longevity testing was performed on a subset of the monofilaments by subjecting them to continuous compressions until the buckling force was <9 g. RESULTS: The accuracy of monofilaments to produce a buckling force of 10 g varies among manufacturers. Bailey Instruments and Owen Mumford filaments were the most accurate with 100% buckling within +/-1.0 g of 10 g. Only 70% of the Semmes-Weinstein monofilaments from North Coast Medical buckled within +/-1.0 g of 10 g. A total of 80% of Timesco filaments buckled at <8 g. Longevity tests on Bailey Instruments and Owen Mumford monofilaments demonstrated that 80% continued to buckle within 10% of 10 g after 100 compressions, but only 50% were within this range after 200 compressions. The maximum amount of recovery achieved in any monofilament occurred within 24 h. CONCLUSIONS: Monofilaments made by either Bailey Instruments or Owen Mumford are recommended for use in clinical practice. North Coast Medical monofilaments may operate differently in the U.S. because of different environmental conditions such as differences in humidity. Timesco/Sensory Testing Systems monofilaments were neither accurate enough nor Conformity European marked to recommend their use in the U.K. Longevity and recovery testing suggest that each monofilament will survive usage on approximately 10 patients before needing a recovery time of 24 h before further use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Preventing Foot Ulcers in Patients With Diabetes
Singh, N. (2005) · JAMA · doi:10.1001/jama.293.2.217 · Cited by 3,097
Boulton (2008) · doi:10.2337/dc08-9021 · Cited by 928
“Single-use disposable monofilaments or those shown to be accurate by the Booth and Young (23) study are recommended.”
BackgroundBoulton, A. J. M., Malik, R. A., Arezzo, J. C., & Sosenko, J. M. (2004) · Diabetes Care · doi:10.2337/diacare.27.6.1458 · Cited by 913
The diabetic foot: from art to science. The 18th Camillo Golgi lecture
Boulton, A. J. M. (2004) · Diabetologia · doi:10.1007/s00125-004-1463-y · Cited by 370
Petersen, E. A., Stauss, T. G., Scowcroft, J. A., Brooks, E. S., White, J. L., Sills, S. M., Amirdelfan, K., Guirguis, M. N., Xu, J., Yu, C., et al. (2021) · JAMA Neurology · doi:10.1001/jamaneurol.2021.0538 · Cited by 277
Vinik, A. I., & Mehrabyan, A. (2004) · Medical Clinics of North America · doi:10.1016/j.mcna.2004.04.009 · Cited by 229
“A final caution on the use of the filaments: Booth and Young [88] identified that filaments manufactured by certain companies do not actually buckle at 10-g force.”
Background
Metadata
- Authors
- Booth, J., & Young, M. J.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2000-07-01
- Volume
- 23
- Issue
- 7
- Pages
- 984-988
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2138910276
- Cited by
- 151
- References
- 0
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.