Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison of continuous subcutaneous insulin infusion and multiple daily injection regimens using insulin lispro in type 1 diabetic patients on intensified treatment: a randomized study. The Study Group for the Development of Pump Therapy in Diabetes.

Open access
Hanaire-Broutin, H, Melki, V, Bessières-Lacombe, S, Tauber, J P·2000·Diabetes Care

Abstract

OBJECTIVE: To compare the efficacy of 2 intensified insulin regimens, continuous subcutaneous insulin infusion (CSII) and multiple daily injections (MDI), by using the short-acting insulin analog lispro in type 1 diabetic patients. RESEARCH DESIGN AND METHODS: A total of 41 C-peptide-negative type 1 diabetic patients (age 43.5+/-10.3 years; 21 men and 20 women, BMI 24.0+/-2.4 kg/m2, diabetes duration 20.0+/-11.3 years) on intensified insulin therapy (MDI with regular insulin or lispro, n = 9, CSII with regular insulin, n = 32) were included in an open-label randomized crossover study comparing two 4-month periods of intensified insulin therapy with lispro: one period by MDI and the other by CSII. Blood glucose (BG) was monitored before and after each of the 3 meals each day. RESULTS: The basal insulin regimen had to be optimized in 75% of the patients during the MDI period (mean number of NPH injections per day = 2.65). HbA1c values were lower when lispro was used in CSII than in MDI (7.89+/-0.77 vs. 8.24+/-0.77%, P<0.001). BG levels were lower with CSII (165+/-27 vs. 175+/-33 mg/dl, P<0.05). The SD of all the BG values (73+/-15 vs. 82+/-18 mg/dl, P<0.01) was lower with CSII. The frequency of hypoglycemic events, defined as BG levels <60 mg/dl, did not differ significantly between the 2 modalities (CSII 3.9+/-4.2 per 14 days vs. MDI 4.3+/-3.9 per 14 days). Mean insulin doses were significantly lower with CSII than with MDI (38.5+/-9.8 vs. 47.3+/-14.9 U/day. respectively, P< 0.0001). CONCLUSIONS: When used with external pumps versus MDI, lispro provides better glycemic control and stability with much lower doses of insulin and does not increase the frequency of hypoglycemic episodes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/diacare.23.9.1232

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
Hanaire-Broutin, H., Melki, V, Bessières-Lacombe, S., & Tauber, J. P.
Venue
Diabetes Care
Published
2000-09-01
Volume
23
Issue
9
Pages
1232-1235
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2034756707
Cited by
174
References
1
FWCI
7.54
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of continuous subcutaneous insulin infusion and multiple daily injection regimens using insulin lispro in type 1 diabetic patients on intensified treatment: a randomized study. The Study Group for the Development of Pump Therapy in Diabetes. https://app.cochat.ai/papers/10.2337/diacare.23.9.1232
The paper
Hanaire-Broutin, H., Melki, V, Bessières-Lacombe, S., & Tauber, J. P. (2000). Comparison of continuous subcutaneous insulin infusion and multiple daily injection regimens using insulin lispro in type 1 diabetic patients on intensified treatment: a randomized study. The Study Group for the Development of Pump Therapy in Diabetes. Diabetes Care. https://doi.org/10.2337/diacare.23.9.1232

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.