Efficacy, Safety, and Pump Compatibility of Insulin Aspart Used in Continuous Subcutaneous Insulin Infusion Therapy in Patients With Type 1 Diabetes
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE— The purpose of this study was to compare the efficacy, safety, and pump compatibility of insulin aspart (a rapid-acting insulin analog) and buffered regular human insulin in patients with type 1 diabetes undergoing continuous subcutaneous insulin infusion (CSII)therapy. RESEARCH DESIGN AND METHODS— This was a single-center randomized openlable study. Patients received CSII therapy with insulin aspart(n = 19) or buffered regular human insulin (n = 10) for 7 weeks. Bolus doses of insulin aspart were administered immediately before meals and buffered regular human insulin 30 min before meals. RESULTS— Insulin aspart and buffered regular human insulin were both effective in controlling average daily blood glucose levels (8.2± 1.9 and 8.5 ± 2.1 mmol/l, respectively) (mean ± SD) and maintaining serum fructosamine (343 ± 25.7 and 336 ± 27.4μmol/l) and HbAlc (6.9 ± 0.6 and 7.1 ± 0.6 %)levels. Possible obstructions and set leakages were infrequently reported in both groups. Similar numbers of patients experienced hypoglycemia (blood glucose <2.5 mmol/l): 14 (74%) insulin aspart patients versus 6 (60%)buffered regular human insulin patients. Patients receiving insulin aspart had fewer hypoglycemic events per patient (2.9) than those patients receiving buffered regular human insulin (6.2). There were no differences between the two insulins in the occurrence of hyperglycemic events (blood glucose >19 mmol/l) or in the number and type of adverse events. CONCLUSIONS— Insulin aspart and buffered regular human insulin were effective and well tolerated and provided similar pump compatibility when used in CSII therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mudaliar, S. R., Lindberg, F. A., Joyce, M., Beerdsen, P., Strange, P., Lin, A., & Henry, R. R. (1999) · Diabetes Care · doi:10.2337/diacare.22.9.1501 · Cited by 276
Self-citationBode, B. W., Steed, R. D., & Davidson, P. C. (1996) · Diabetes Care · doi:10.2337/diacare.19.4.324 · Cited by 257
Self-citation
Cited by
Sarnak, M. J., Levey, A. S., Schoolwerth, A. C., Coresh, J., Culleton, B., Hamm, L. L., McCullough, P. A., Kasiske, B. L., Kelepouris, E., Klag, M. J., et al. (2003) · Circulation · doi:10.1161/01.cir.0000095676.90936.80 · Cited by 3,768
Ärnlöv, J., Evans, J. C., Meigs, J. B., Wang, T. J., Fox, C. S., Levy, D., Benjamin, E. J., D’Agostino, R. B., & Vasan, R. S. (2005) · Circulation · doi:10.1161/circulationaha.105.538132 · Cited by 736
Outpatient Insulin Therapy in Type 1 and Type 2 Diabetes Mellitus: Scientific Review
DeWitt, D. E., & Hirsch, I. B. (2003) · JAMA · doi:10.1001/jama.289.17.2254 · Cited by 502
Continuous Subcutaneous Insulin Infusion at 25 Years
Pickup, J., & Keen, H. (2002) · Diabetes Care · doi:10.2337/diacare.25.3.593 · Cited by 397
Garg, A. X., Kiberd, B. A., Clark, W. F., Haynes, R. B., & Clase, C. M. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00356.x · Cited by 355
Metadata
- Authors
- Bode, B. W., & Strange, P.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2001-01-01
- Volume
- 24
- Issue
- 1
- Pages
- 69-72
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2123165496
- Cited by
- 113
- References
- 2
- FWCI
- 9.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy, Safety, and Pump Compatibility of Insulin Aspart Used in Continuous Subcutaneous Insulin Infusion Therapy in Patients With Type 1 Diabetes. https://app.cochat.ai/papers/10.2337/diacare.24.1.69
- The paper
- Bode, B. W., & Strange, P. (2001). Efficacy, Safety, and Pump Compatibility of Insulin Aspart Used in Continuous Subcutaneous Insulin Infusion Therapy in Patients With Type 1 Diabetes. Diabetes Care. https://doi.org/10.2337/diacare.24.1.69
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.