The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Frequency of Blood Glucose Monitoring in Relation to Glycemic Control in Patients With Type 2 Diabetes
Open accessAbstract
OBJECTIVE—The aim of the study was to investigate the relationship between blood glucose level, measured as HbA1c, and frequency of self-monitoring in patients with type 2 diabetes. Daily self-monitoring is believed to be important for patients treated with insulin or oral agents to detect asymptomatic hypoglycemia and to guide patient and provider behavior toward reaching blood glucose goals. RESEARCH DESIGN AND METHODS—A national sample of patients with type 2 diabetes was studied in the third National Health and Nutrition Examination Survey. Data on therapy for diabetes, frequency of self-monitoring of blood glucose, and HbA1c values were obtained by structured questionnaires and by clinical and laboratory assessments. RESULTS—According to the data, 29% of patients treated with insulin, 65% treated with oral agents, and 80% treated with diet alone had never monitored their blood glucose or monitored it less than once per month. Self-monitoring at least once per day was practiced by 39% of those taking insulin and 5–6% of those treated with oral agents or diet alone. For all patients combined, the proportion of patients who tested their blood glucose increased with an increasing HbA1c value. However, when examined by diabetes therapy category, there was little relationship between HbA1c value and the proportion testing at least once per day or the proportion testing at least once per week. CONCLUSIONS—In this cross-sectional study of patients with type 2 diabetes, the increase in frequency of self-monitoring of blood glucose with increasing HbA1c value was associated with the higher proportion of insulin-treated patients in higher HbA1c categories. Within diabetes therapy categories, the frequency of self-monitoring was not related to glycemic control, as measured by HbA1c level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harris, M. I., Flegal, K. M., Cowie, C. C., Eberhardt, M. S., Goldstein, D. E., Little, R. R., Wiedmeyer, H.-M., & Byrd-Holt, D. D. (1998) · Diabetes Care · doi:10.2337/diacare.21.4.518 · Cited by 2,703
Self-citation
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
A history of blood glucose meters and their role in self-monitoring of diabetes mellitus
Clarke, S. F., & Foster, J. R. (2012) · British Journal of Biomedical Science · doi:10.1080/09674845.2012.12002443 · Cited by 456
Assessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A 1c
Saudek, C. D., Derr, R. L., & Kalyani, R. R. (2006) · JAMA · doi:10.1001/jama.295.14.1688 · Cited by 373
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Malanda, U. L., Welschen, L. M., Riphagen, I. I., Dekker, J. M., Nijpels, G., & Bot, S. D. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub3 · Cited by 358
Metadata
- Authors
- Harris, M. I.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2001-06-01
- Volume
- 24
- Issue
- 6
- Pages
- 979-982
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2150014941
- Cited by
- 246
- References
- 1
- FWCI
- 11.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency of Blood Glucose Monitoring in Relation to Glycemic Control in Patients With Type 2 Diabetes. https://app.cochat.ai/papers/10.2337/diacare.24.6.979
- The paper
- Harris, M. I. (2001). Frequency of Blood Glucose Monitoring in Relation to Glycemic Control in Patients With Type 2 Diabetes. Diabetes Care. https://doi.org/10.2337/diacare.24.6.979
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.