The Influence of Age, Duration of Diabetes, Cataract, and Pupil Size on Image Quality in Digital Photographic Retinal Screening
The DOI matches its Crossref record.
Abstract
OBJECTIVE—To evaluate the effect of age, duration of diabetes, cataract, and pupil size on the image quality in digital photographic screening. RESEARCH DESIGN AND METHODS—Randomized groups of 3,650 patients had one-field, nonmydriatic, 45° digital retinal imaging photography before mydriatic two-field photography. A total of 1,549 patients were then examined by an experienced ophthalmologist. Outcome measures were ungradable image rates, age, duration of diabetes, detection of referable diabetic retinopathy, presence of early or obvious central cataract, pupil diameter, and iris color. RESULTS—The ungradable image rate for nonmydriatic photography was 19.7% (95% CI 18.4–21.0) and for mydriatic photography was 3.7% (3.1–4.3). The odds of having one eye ungradable increased by 2.6% (1.6–3.7) for each extra year since diagnosis for nonmydriatic, by 4.1% (2.7–5.7) for mydriatic photography irrespective of age, by 5.8% (5.0–6.7) for nonmydriatic, and by 8.4% (6.5–10.4) for mydriatic photography for every extra year of age, irrespective of years since diagnosis. Obvious central cataract was present in 57% of ungradable mydriatic photographs, early cataract in 21%, no cataract in 9%, and 13% had other pathologies. The pupil diameter in the ungradable eyes showed a significant trend (P < 0.001) in the three groups (obvious cataract 4.434, early cataract 3.379, and no cataract 2.750). CONCLUSIONS—The strongest predictor of ungradable image rates, both for nonmydriatic and mydriatic digital photography, is the age of the person with diabetes. The most common cause of ungradable images was obvious central cataract.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rajalakshmi, R., Subashini, R., Anjana, R. M., & Mohan, V. (2018) · Eye · doi:10.1038/s41433-018-0064-9 · Cited by 462
The English National Screening Programme for diabetic retinopathy 2003–2016
Scanlon, P. H. (2017) · Acta Diabetologica · doi:10.1007/s00592-017-0974-1 · Cited by 440
Self-citationPrevalence of Age-Related Macular Degeneration in the US in 2019
Rein, D. B., Wittenborn, J. S., Burke-Conte, Z., Gulia, R., Robalik, T., Ehrlich, J. R., Lundeen, E. A., & Flaxman, A. D. (2022) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2022.4401 · Cited by 275
Li, Z., Keel, S., Liu, C., He, Y., Meng, W., Scheetz, J., Lee, P. Y., Shaw, J., Ting, D., Wong, T. Y., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0147 · Cited by 255
“In real-world screening settings, rates of poor-quality or ungradable images have been reported to be as high as 20% (34,35).”
BackgroundValidation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening
Rajalakshmi, R., Arulmalar, S., Usha, M., Prathiba, V., Kareemuddin, K. S., Anjana, R. M., & Mohan, V. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138285 · Cited by 173
“In our study, there were no ungradable images in the fundus photographs taken with either of the cameras as none of the recruited patients had very dense cataract or total vitreous hemorrhage [18, 23].”
Background
Metadata
- Authors
- Scanlon, P. H., Foy, C., Malhotra, R., & Aldington, S. J.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2005-10-01
- Volume
- 28
- Issue
- 10
- Pages
- 2448-2453
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2068376589
- Cited by
- 137
- References
- 0
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Influence of Age, Duration of Diabetes, Cataract, and Pupil Size on Image Quality in Digital Photographic Retinal Screening. https://app.cochat.ai/papers/10.2337/diacare.28.10.2448
- The paper
- Scanlon, P. H., Foy, C., Malhotra, R., & Aldington, S. J. (2005). The Influence of Age, Duration of Diabetes, Cataract, and Pupil Size on Image Quality in Digital Photographic Retinal Screening. Diabetes Care. https://doi.org/10.2337/diacare.28.10.2448
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.