continuous Subcutaneous Insulin Infusion in the Treatment of Diabetes Mellitus
Abstract
Low-volume, dual-rate, continuous subcutaneous insulin infusion (CSII) creates long periods of nearnormalization of blood glucose and major intermediary metabolites in most insulin-requiring diabetic patients. The technology and strategy of the system are discussed. We have observed encouraging clinical and fluorescein angiographic improvement in severe diabetic retinopathy after 3 mo of outpatient CSII; in the kidney, glomerular capillary permeability (microalbuminuria) is reduced or normalized in long-standing diabetic patients after a few days of CSII-induced strict control. Reduction in insulin dose during CSII treatment of newly diagnosed ketonuric diabetic patients may indicate improved B-cell function in this group. Although CSII must remain a research tool, undertaken only under close medical supervision, it is increasingly likely that the technique affords the conditions for testing the hypothesis that metabolic near-normalization of diabetes slows, arrests, or reverses the course of the microvascular disease associated with the syndrome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
Continuous Subcutaneous Insulin Infusion at 25 Years
Pickup, J., & Keen, H. (2002) · Diabetes Care · doi:10.2337/diacare.25.3.593 · Cited by 397
Self-citationViberti, G. C., Bilous, R. W., Mackintosh, D., Bending, J. J., & Keen, H. (1983) · BMJ · doi:10.1136/bmj.286.6365.598 · Cited by 254
Self-citationLittle, S. A., Speight, J., Leelarathna, L., Walkinshaw, E., Tan, H. K., Bowes, A., Lubina-Solomon, A., Chadwick, T. J., Stocken, D. D., Brennand, C., et al. (2018) · Diabetes Care · doi:10.2337/dc17-2682 · Cited by 86
Metadata
- Authors
- Pickup, J. C., Keen, H., Viberti, G. C., White, M. C., Kohner, E. M., Parsons, J. A., & Alerti, K. G. M. M.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1980-03-01
- Volume
- 3
- Issue
- 2
- Pages
- 290-300
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W1992027559
- Cited by
- 175
- References
- 0
- FWCI
- 15.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: continuous Subcutaneous Insulin Infusion in the Treatment of Diabetes Mellitus. https://app.cochat.ai/papers/10.2337/diacare.3.2.290
- The paper
- Pickup, J. C., Keen, H., Viberti, G. C., White, M. C., Kohner, E. M., Parsons, J. A., & Alerti, K. G. M. M. (1980). continuous Subcutaneous Insulin Infusion in the Treatment of Diabetes Mellitus. Diabetes Care. https://doi.org/10.2337/diacare.3.2.290
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.