Continuous Subcutaneous Insulin Infusion (Mill-Hill Infuser) Versus Multiple Injections (Medi-Jector) in the Treatment of Insulin-dependent Diabetes Mellitus and the Effect of Metabolic Control on Microangiopathy
The DOI matches its Crossref record.
Abstract
The present study was designed to compare continuous subcutaneous insulin infusion (CSII) using the Mill-Hill Infuser (Muirhead Medical Products Ltd., London, England) with multiple injections (MI) using the Medi-Jector (Derata Corporation, Minneapolis, Minnesota)in the treatment of insulin-dependent diabetes mellitus (IDDM), and to assess the effect of glucose control on diabetes complications. Twelve diabetic subjects were treated 3 mo with CSII and 3 mo with MI (bedtime ultralente and premeal boluses of regular insulin) ina randomized fashion. Prestudy preprandial/postprandial glucose levels were 147–215 mg/dl and improved to 108–138 mg/dl during CSII, and to 115–139 mg/dl during MI with glycosylated hemoglobin of 12.9%, 9.1%, and 8.7%, respectively. This improved glucose control with either CSII or MI was associated with an increase in sural nerve conductivity from 42.9 to 45 m/s and a decrease in proteinuria from 1.9 to 0.5 g/24 h. The 24-h insulin dose consisted of 45 U before the study, 44 U during CSII, and 56 U during MI. After the study, seven patients opted to continue with the Mill-Hill Infuser, and five with the Medi-Jector. We conclude the following: (1) treatment with both the Mill-Hill Infuser and the Medi-Jectorwas well accepted by the patients and resulted in similar improvement in measured blood glucose and glycosylated hemoglobin; (2) this improved metabolic control was associated with an increased nerve conductivity and a decreased protein excretion; and (3) MI required20% more insulin than CSII to achieve similar glycemic control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Misso, M. L., Egberts, K. J., Page, M., O'Connor, D., & Shaw, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005103.pub2 · Cited by 406
Jeitler, K., Horvath, K., Berghold, A., Gratzer, T. W., Neeser, K., Pieber, T. R., & Siebenhofer, A. (2008) · Diabetologia · doi:10.1007/s00125-008-0974-3 · Cited by 375
Cummins, E., Royle, P., Snaith, A., Greene, A., Robertson, L., McIntyre, L., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14110 · Cited by 335
Pathogenesis of diabetic microangiopathy. The hemodynamic view
Zatz, R., & Brenner, B. M. (1986) · The American Journal of Medicine · doi:10.1016/0002-9343(86)90719-9 · Cited by 320
Heller, S., White, D., Lee, E., Lawton, J., Pollard, D., Waugh, N., Amiel, S., Barnard, K., Beckwith, A., Brennan, A., et al. (2017) · Health Technology Assessment · doi:10.3310/hta21200 · Cited by 73
Metadata
- Authors
- Chiasson, J. L., Ducros, F., Poliquin-Hamet, M., Lopez, D., Lecavalier, L., & Hamet, P.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1984-07-01
- Volume
- 7
- Issue
- 4
- Pages
- 331-337
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2072677269
- Cited by
- 54
- References
- 0
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Subcutaneous Insulin Infusion (Mill-Hill Infuser) Versus Multiple Injections (Medi-Jector) in the Treatment of Insulin-dependent Diabetes Mellitus and the Effect of Metabolic Control on Microangiopathy. https://app.cochat.ai/papers/10.2337/diacare.7.4.331
- The paper
- Chiasson, J. L., Ducros, F., Poliquin-Hamet, M., Lopez, D., Lecavalier, L., & Hamet, P. (1984). Continuous Subcutaneous Insulin Infusion (Mill-Hill Infuser) Versus Multiple Injections (Medi-Jector) in the Treatment of Insulin-dependent Diabetes Mellitus and the Effect of Metabolic Control on Microangiopathy. Diabetes Care. https://doi.org/10.2337/diacare.7.4.331
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.