Standardization of grip strength measurements. Effects on repeatability and peak force
Open accessThe DOI matches its Crossref record.
Abstract
The aim of our study was to test grip strength and assess the effects of various degrees of standardization on repeatability and level of peak force. Sixteen healthy persons and eight subjects with an impaired hand function have been tested using a strain-gauge dynamometer. We compared four measurement protocols: (A) the subject is free to assume a comfortable arm position; (B) the subject is also free to assume a comfortable arm position but in addition a challenging stimulus to exceed a previous maximal effort, is given; (C) the arm was held in a predescribed and partly fixated position, as recommended by the American Society of Hand Therapists; (D) the position of the dynamometer is standardized using two reference points both on the hand and on the dynamometer. We found high test-retest reliabilities for each measurement protocol without any significant difference. There were, however, significant differences in strength level. With measurements according to protocol B the highest peak values were noted. Since the measurement protocol B combined good reliability with realistic peak forces, this procedure seems most suitable for grip strength measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Roberts, H. C., Denison, H. J., Martin, H. J., Patel, H. P., Syddall, H., Cooper, C., & Sayer, A. A. (2011) · Age and Ageing · doi:10.1093/ageing/afr051 · Cited by 3,001
Rondanelli, M., Klersy, C., Terracol, G., Talluri, J., Maugeri, R., Guido, D., Faliva, M. A., Solerte, B. S., Fioravanti, M., Lukaski, H., et al. (2016) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.113357 · Cited by 412
Nordenskiöld, U. M., & Grimby, G. (1993) · Scandinavian Journal of Rheumatology · doi:10.3109/03009749309095105 · Cited by 328
Hand size influences optimal grip span in women but not in men
Ruiz-Ruiz, J., Mesa, J. L. M., Gutiérrez, A., & Castillo, M. J. (2002) · The Journal of Hand Surgery · doi:10.1053/jhsu.2002.34315 · Cited by 263
Roebroeck, M. E., Harlaar, J., & Lankhorst, G. J. (1993) · Physical Therapy · doi:10.1093/ptj/73.6.386 · Cited by 228
Self-citation
Metadata
- Authors
- Spijkerman, D., Snijders, C., Stijnen, T., & Lankhorst, G.
- Venue
- Journal of Rehabilitation Medicine
- Published
- 2020-04-29
- Volume
- 23
- Issue
- 4
- Pages
- 203-206
- ISSN
- 1650-1977 (ISSN-L)
- 1651-2081
- OpenAlex
- W71814872
- Cited by
- 77
- References
- 0
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Standardization of grip strength measurements. Effects on repeatability and peak force. https://app.cochat.ai/papers/10.2340/165019779123203206
- The paper
- Spijkerman, D., Snijders, C., Stijnen, T., & Lankhorst, G. (2020). Standardization of grip strength measurements. Effects on repeatability and peak force. Journal of Rehabilitation Medicine. https://doi.org/10.2340/165019779123203206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.