Comparison of the Jamar dynamometer and the Martin vigorimeter for grip strength measurements in a healthy elderly population.
Open accessThe DOI matches its Crossref record.
Abstract
Grip strength is considered to be a good indicator of upper limb strength. The Jamar dynamometer and the Martin vigorimeter are two instruments frequently used to assess grip strength in clinical and research settings. The purpose of this study was to compare these instruments for assessing grip strength in 360 people aged 60 to 94 years, randomly selected from the electoral list. Anthropometric data were also collected. Data analyses were done using the maximum value on 3 trials with each instrument. Although the Martin vigorimeter is a pressure measure implying a dynamic movement as opposed to the static strength measure of the Jamar dynamometer, results indicate a very high correlation between the two measures. Grip strength measured by the Jamar dynamometer is even more dependent on hand anthropometry than measurements with the Martin vigorimeter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effects of Vitamin D and Calcium Supplementation on Falls: A Randomized Controlled Trial
Bischoff, H. A., Stähelin, H. B., Dick, W., Akos, R., Knecht, M., Salis, C., Nebiker, M., Theiler, R., Pfeifer, M., Begerow, B., et al. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.2.343 · Cited by 980
Mijnarends, D. M., Meijers, J. M. M., Halfens, R. J. G., ter Borg, S., Luiking, Y. C., Verlaan, S., Schoberer, D., Cruz Jentoft, A. J., van Loon, L. J. C., & Schols, J. M. G. A. (2013) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2012.10.009 · Cited by 475
Rijk, J. M., Roos, P. R., Deckx, L., van den Akker, M., & Buntinx, F. (2016) · Geriatrics & Gerontology International · doi:10.1111/ggi.12508 · Cited by 376
Differences in handgrip strength protocols to identify sarcopenia and frailty - a systematic review
Sousa-Santos, A. R., & Amaral, T. F. (2017) · BMC Geriatrics · doi:10.1186/s12877-017-0625-y · Cited by 273
Tools in the Assessment of Sarcopenia
Cooper, C., Fielding, R., Visser, M., van Loon, L. J., Rolland, Y., Orwoll, E., Reid, K., Boonen, S., Dere, W., Epstein, S., et al. (2013) · Calcified Tissue International · doi:10.1007/s00223-013-9757-z · Cited by 246
“In these instances, the Martin vigorimeter, which measures grip strength using rubber balls available in three different sizes, may be a suitable alternative [50].”
Metadata
- Authors
- Desrosiers, J., Hébert, R., Bravo, G., & Dutil, E.
- Venue
- Journal of Rehabilitation Medicine
- Publisher
- Medical Journals Sweden AB
- Published
- 2020-05-05
- Volume
- 27
- Issue
- 3
- Pages
- 137-143
- ISSN
- 1650-1977 (ISSN-L)
- 1651-2081
- OpenAlex
- W109333748
- Cited by
- 114
- References
- 0
- FWCI
- 1.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of the Jamar dynamometer and the Martin vigorimeter for grip strength measurements in a healthy elderly population. https://app.cochat.ai/papers/10.2340/165019779527137143
- The paper
- Desrosiers, J., Hébert, R., Bravo, G., & Dutil, E. (2020). Comparison of the Jamar dynamometer and the Martin vigorimeter for grip strength measurements in a healthy elderly population. Journal of Rehabilitation Medicine. https://doi.org/10.2340/165019779527137143
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.