Portable open-circuit spirometry systems
The DOI matches its Crossref record.
Abstract
The purpose of this review is to describe the evolution of portable open-circuit spirometry systems, and discuss their validity, reliability, and principles of operation.Eleven devices were selected for review: the Oxylog, Aerosport KB1-C, Cosmed K2, Cosmed K4RQ, Cosmed K4b2, MetaMax I, MetaMax II, Metamax3B/VmaxST, Medgraphics VO2000, Oxycon Mobile I and Oxycon Mobile II. The validity (compared to the Douglas bag method [DBM]) and reliability of each device for measuring VO2 was summarized.Mean differences in resting measurements of VO2 were within ±0.05 L/min for all devices except one (difference of 0.17 L/min). When compared to the DBM, VO2 differences for all devices ranged from 0.01 L/min to 0.29 L/min during submaximal intensity exercise and from 0.01 L/min to 0.36 L/min during vigorous/maximal intensity. During submaximal and maximal intensities, ICC ranged from 0.66-0.99 and CV ranged from 2.0-14.2%. Of these devices, four used breath-by-breath technology and six used micro-proportional sampling technology. Validity and reliability of devices did not seem to differ between methods of gas collection.Of the three commercially available devices in 2015, all were found to be reliable. Two of the three systems (Cosmed K4b2 and Oxycon Mobile II) provided valid estimates of VO2 (mean values within ±0.10 L/min of DBM) during rest, and submaximal and maximal intensities, while the MetaMax3B slightly overestimated VO2, particularly at maximal exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise
Crum, E. M., O'Connor, W. J., Van Loo, L., Valckx, M., & Stannard, S. R. (2017) · European Journal of Sport Science · doi:10.1080/17461391.2017.1330899 · Cited by 206
Physiological demands of running at 2-hour marathon race pace
Jones, A. M., Kirby, B. S., Clark, I. E., Rice, H. M., Fulkerson, E., Wylie, L. J., Wilkerson, D. P., Vanhatalo, A., & Wilkins, B. W. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00647.2020 · Cited by 200
“The principles of operation of the two systems are similar and 130 it has been reported that they provide measurements of V̇O2 that are reliable and valid 131 relative to the gold standard Douglas bag method (1, 25, 51).”
MethodResultEnergy system contribution during competitive cross-country skiing
Losnegard, T. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04158-x · Cited by 99
Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment
(2020) · International Journal of Exercise Science · doi:10.70252/thjt1177 · Cited by 39
“Brands of portable analyzers including COSMED, Oxycon, and MetaMax have received extensive validation and field use in a variety of settings, providing evidence of the importance of capturing such field-based data (19, 24).”
BackgroundRębiś, K., Sadowska, D., Starczewski, M., & Klusiewicz, A. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.809864 · Cited by 12
Rębiś, K., Klusiewicz, A., Długołęcka, B., Różański, P., Kowieski, K., & Kowalski, T. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13175340 · Cited by 7
“The gas analyser was previously demonstrated as a reliable tool for measuring oxygen uptake [28].”
Method
Metadata
- Authors
- Overstreet, B. S., Bassett Jr., D. R., Crouter, S. E., Rider, B. C., & Parr, B. B.
- Venue
- The Journal of Sports Medicine and Physical Fitness
- Publisher
- Edizioni Minerva Medica
- Published
- 2017-01
- Volume
- 57
- Issue
- 3
- ISSN
- 0022-4707 (ISSN-L)
- 1827-1928
- OpenAlex
- W2899813149
- Cited by
- 48
- References
- 0
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.