Overview of fault diagnosis theory and method for permanent magnet machine
Open accessThe DOI matches its Crossref record.
Abstract
Permanent magnet (PM) machines have been widely used in a variety of industrial and military applications due to their definite advantages of high power density and high efficiency. In some applications such as electric vehicles (EVs) and aircrafts, high reliability and security of the PM machine are critical. Hence, there is rapidly growing interest in strategies to improve the reliability and security of the PM machine from both academia and industry, where fault diagnosis is a requirement. In this paper, common faults of the PM machine are discussed, state of the art in fault diagnosis of PM machine are overviewed in detail, and different fault diagnosis methods are analyzed and compared. Finally, the development tendency of fault diagnosis techniques for the PM machine is prospected.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This drawback can be eliminated by using the flux-based and BEMF methods which are capable of detecting both uniform and local demagnetization [15], [19], [29], [30], [32].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [15]
In the citing paper
“Bearing damage leads to eccentricity, increased friction between the stator and rotor, and in extreme cases to ITSCs or insulation fire [15], [17], [24].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [15]
Citations
Cites
Still being checked.
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Improved ZSVC‐based fault detection technique for incipient stage inter‐turn fault in PMSM
Fang, J., Sun, Y., Wang, Y., Wei, B., & Hang, J. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0016 · Cited by 30
Self-citation
Metadata
- Authors
- Cheng, M., Hang, J., & Zhang, J.
- Affiliations
- Southeast University (CN)
- Venue
- Chinese Journal of Electrical Engineering
- Published
- 2015-12
- Volume
- 1
- Issue
- 1
- Pages
- 21-36
- ISSN
- 2096-1529 (ISSN-L)
- OpenAlex
- W3020105602
- Cited by
- 81
- References
- 0
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 13 · 2023: 10 · 2022: 10 · 2021: 8 · 2020: 4 · 2019: 6 · 2018: 5 · 2017: 4 · 2016: 10
- FWCI
- 5.84
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- cc-by
- Locations
- Chinese Journal of Electrical Engineering (publishedVersion, cc-by)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet machines, fault diagnosis, electric vehicles, machine reliability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Overview of fault diagnosis theory and method for permanent magnet machine. https://app.cochat.ai/papers/10.23919/cjee.2015.7933135
- The paper
- Cheng, M., Hang, J., & Zhang, J. (2015). Overview of fault diagnosis theory and method for permanent magnet machine. Chinese Journal of Electrical Engineering. https://doi.org/10.23919/cjee.2015.7933135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.