Applying FHIR in an Integrated Health Monitoring System
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The continuous monitoring of vital signs has become an important supplement to traditional medical treatment to ensure the success of a therapy.Integrated health monitoring solutions based on existing health standards provide interoperability and enable healthcare providers and patients to exchange and access their data across institutional borders.This paper shows an integrated monitoring solution based on Continua and Integrating the Healthcare Enterprise, which has been tested by more than 130 patients and 14 healthcare institutions.According to user feedback, one recurring problem is the low battery life of smartphones due to high data traffic.Since the recently developed HL7 standard FHIR offers a resource efficient handling of web service connections, a possible approach to extend the monitoring solution to support FHIR.Comparing both solutions using data collected by 68 patients, it can be concluded that there is a significant decrease in data traffic when relying on a RESTful architecture in combination with FHIR.For productive use of the FHIR-based approach shown in this paper, security related concerns have to be taken into account in future work to ensure authenticity and authorization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
HL7 FHIR: An Agile and RESTful approach to healthcare information exchange
Bender, D., & Sartipi, K. (2013) · Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems · doi:10.1109/cbms.2013.6627810 · Cited by 540
Cited by
Ayaz, M., Pasha, M. F., Alzahrani, M. Y., Budiarto, R., & Stiawan, D. (2021) · JMIR Medical Informatics · doi:10.2196/21929 · Cited by 284
“From a platform point of view, we considered the implementation of mobile/tablet apps [3,9,28,35,39,51,57,60,65,70,72,77,82], standalone apps/servers [3,23,51,58,61], web services/API [3,11,14,26,34,36, 40,48,53,56,71,78], and web-based tools/applications [18,26,37,40,42,46,55,69,78] categories.”
BackgroundFast Health Interoperability Resources (FHIR): Current Status in the Healthcare System
Saripalle, R. K. (2019) · International Journal of E-Health and Medical Communications · doi:10.4018/ijehmc.2019010105 · Cited by 50
Achieving RBAC on RESTful APIs for Mobile Apps Using FHIR
Rivera Sanchez, Y. K., Demurjian, S. A., & Baihan, M. S. (2017) · 2017 5th IEEE International Conference on Mobile Cloud Computing, Services, and Engineering (MobileCloud) · doi:10.1109/mobilecloud.2017.22 · Cited by 21
Metadata
- Authors
- Franz, B.
- Venue
- European Journal for Biomedical Informatics
- Publisher
- OMICS Publishing Group
- Published
- 2015
- Volume
- 11
- Issue
- 02
- ISSN
- 1801-5603 (ISSN-L)
- OpenAlex
- W2562676124
- Cited by
- 37
- References
- 1
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Applying FHIR in an Integrated Health Monitoring System. https://app.cochat.ai/papers/10.24105/ejbi.2015.11.2.8
- The paper
- Franz, B. (2015). Applying FHIR in an Integrated Health Monitoring System. European Journal for Biomedical Informatics. https://doi.org/10.24105/ejbi.2015.11.2.8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.