Low-Power Current-Mode Resistive Readout Circuit Using 0.13µm Technology for biomedical MEMS applications
Open accessAbstract
This paper presents an innovative current-mode interface circuit design specifically for resistive readout circuits.The main goal is to create and evaluate resistive readout circuits utilizing a current-mode architecture.The design and simulation of the resistive readout circuit are conducted using Silterra's 0.13µm technology, powered by a 1.2V supply voltage, with the aid of Cadence ADE.This architecture is optimized for low power consumption, drawing only 15µW, while maintaining high sensitivity for resistive values ranging from 500KΩ to 199MΩ.The circuit's output voltage varies between 0.48V and 1.03V, allowing for precise measurement and analysis of resistive sensor data.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 26
- Authors
- Karim, J.
- Affiliations
- Universiti Teknologi MARA System (MY)
- Corresponding author
- Karim, Jamilah
- ORCID
- Karim, Jamilah
- Venue
- Journal of Electrical & Electronic Systems Research
- Published
- 2025-04-30
- Volume
- 26
- Issue
- APR2025
- Pages
- 57-63
- ISSN
- 1985-5389 (ISSN-L)
- OpenAlex
- W4410718616
- Cited by
- 0
- References
- 26
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Locations
- Journal of Electrical & Electronic Systems Research (publishedVersion)
- UiTM Institutional Repositories (Universiti Teknologi MARA) (acceptedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Physical Sciences › Computer Science › Computer Networks and Communications › Sensor Technology and Measurement Systems
- Keywords
- low power design, resistive sensors, low-voltage operation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review