Atrioventricular conduction after alcohol septal ablation for obstructive hypertrophic cardiomyopathy
The DOI matches its Crossref record.
Abstract
AIMS: Lesion of the atrioventricular conduction system is a well known adverse effect of alcohol septal ablation (ASA) in patients with obstructive hypertrophic cardiomyopathy (HCM). We assessed the atrioventricular conduction at long-term follow-up after ASA. METHODS: In patients with a pacemaker implanted for high-grade atrioventricular block after ASA, the atrioventricular conduction was assessed prospectively by ECGs and 48-h Holter recordings. In the remaining patients, the atrioventricular conduction was analysed retrospectively for comparison. RESULTS: A total of 24 (28%) of 87 patients with obstructive HCM without a pacemaker at baseline had a pacemaker implanted due to high-grade atrioventricular block after ASA. Ten of these patients were not available for follow-up. Holter recordings in the remaining 14 patients revealed normalized atrioventricular conduction in 6 patients 6.2 years (range 2.1-9.4) after ASA. Patients with high-grade atrioventricular block at follow-up had longer PR intervals at baseline [205 ms (200-230)] than the rest of the cohort [180 ms (140-200), P = 0.004] and a higher incidence of acute complete heart block (63 vs. 15%; P = 0.007) during ASA. A PR interval of at least 200 ms at baseline was associated with higher prevalence of high-grade atrioventricular block at follow-up (30 vs. 2%; P = 0.0013). The incidence of late-onset complete heart block was 1.5% per year after ASA. CONCLUSION: We found normalized atrioventricular conduction at long-term follow-up, suggesting recovery in 6 of 14 patients with a pacemaker implanted in relation to ASA. Permanent atrioventricular conduction abnormalities were associated with baseline PR intervals of at least 200 ms and acute persistent complete heart block during ASA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.043 · Cited by 337
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000627 · Cited by 160
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Metadata
- Authors
- Axelsson, A., Weibring, K., Havndrup, O., Kelbæk, H., Jørgensen, E., Helqvist, S., Iversen, K., Køber, L., Bundgaard, H., & Jensen, M. K.
- Venue
- Journal of Cardiovascular Medicine
- Published
- 2014-03
- Volume
- 15
- Issue
- 3
- Pages
- 214-221
- ISSN
- 1558-2027 (ISSN-L)
- OpenAlex
- W2321739318
- Cited by
- 19
- References
- 0
- FWCI
- 0.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.