Clinical comparison of three methods to measure blood pressure in nonsedated dogs
Open accessThe DOI matches its Crossref record.
Abstract
Objective: To determine arterial blood pressure in client-owned dogs, using direct arterial puncture, oscillometry, and Doppler ultrasonography in a clinical setting. Design: Prospective study. Animals: 28 clinically normal client-owned dogs. Procedure: Blood pressures of nonsedated dogs were measured simultaneously, using each of the 3 methods. Mean values obtained were compared with published mean values. Ability of noninvasive methods (Doppler ultrasonography and oscillometry) to accurately predict results of the invasive method, and relationships between blood pressure and age, body weight, and degree of patient anxiety were determined. Results: Calculated ranges of values (mean ± 2 SD) determined by direct arterial puncture were: systolic pressure, 114 to 194 mm Hg; diastolic pressure, 66 to 102 mm Hg; and mean pressure, 85 to 129 mm Hg. Ranges determined by use of oscillometry were: systolic, 110 to 190 mm Hg; diastolic, 35 to 107 mm Hg; and mean, 78 to 138 mm Hg. Ultrasonographic and oscillometric values did not accurately predict direct values, but mean values of systolic and mean pressures were similar among methods. Relationships were not detected between age or body weight and blood pressure. Significant differences in blood pressure were not detected between anxious and nonanxious dogs. Conclusions and Clinical Relevance: Mean values of systolic, diastolic, and mean arterial blood pressure measured in nonsedated client-owned dogs, using invasive and noninvasive methods in a clinical setting, are comparable with those determined for acclimatized, trained, or sedated dogs. However, results of noninvasive methods may not accurately reflect direct values. (J Am Vet Med Assoc 1999;215:1623–1628)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brown, S., Atkins, C., Bagley, R., Carr, A., Cowgill, L., Davidson, M., Egner, B., Elliott, J., Henik, R., Labato, M., et al. (2007) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2007.tb03005.x · Cited by 748
Self-citationAcierno, M. J., Brown, S., Coleman, A. E., Jepson, R. E., Papich, M., Stepien, R. L., & Syme, H. M. (2018) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.15331 · Cited by 601
Self-citationStepien, R. L., Rapoport, G. S., Henik, R. A., Wenholz, L., & Thomas, C. B. (2003) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2003.tb01325.x · Cited by 62
Self-citationIndirect measurement of systemic blood pressure in conscious dogs in a clinical setting.
HSIANG, T.-Y., LIEN, Y.-H., & HUANG, H.-P. (2008) · Journal of Veterinary Medical Science · doi:10.1292/jvms.70.449 · Cited by 29
“The systemic blood pressure value can be determined by either a direct (invasive) or indirect (noninvasive) method [3, 4, 6, 10, 15, 17, 19].”
BackgroundMethodValores da pressão arterial em cães pelos métodos oscilométrico e Doppler vascular
Cabral, R. R., Ciasca, B. D., Oliveira, V. M. C., Vaz-Curado, A. P., & Larsson, M. H. M. A. (2010) · Arquivo Brasileiro de Medicina Veterinária e Zootecnia · doi:10.1590/s0102-09352010000100009 · Cited by 15
Metadata
- Authors
- Stepien, R. L., & Rapoport, G. S.
- Venue
- Journal of the American Veterinary Medical Association
- Published
- 1999-12-01
- Volume
- 215
- Issue
- 11
- Pages
- 1623-1628
- ISSN
- 0003-1488 (ISSN-L)
- OpenAlex
- W113447874
- Cited by
- 80
- References
- 0
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical comparison of three methods to measure blood pressure in nonsedated dogs. https://app.cochat.ai/papers/10.2460/javma.1999.215.11.1623
- The paper
- Stepien, R. L., & Rapoport, G. S. (1999). Clinical comparison of three methods to measure blood pressure in nonsedated dogs. Journal of the American Veterinary Medical Association. https://doi.org/10.2460/javma.1999.215.11.1623
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.