The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Comparison of three methods of temperature measurement in hypothermic, euthermic, and hyperthermic dogs
Open accessAbstract
Objective —To assess the reliability and accuracy of a predictive rectal thermometer, an infrared auricular thermometer designed for veterinary use, and a subcutaneous temperature-sensing microchip for measurement of core body temperature over various temperature conditions in dogs. Design —Prospective study. Animals —8 purpose-bred dogs. Procedures —A minimum of 7 days prior to study commencement, a subcutaneous temperature-sensing microchip was implanted in 1 of 3 locations (interscapular, lateral aspect of shoulder, or sacral region) in each dog. For comparison with temperatures measured via rectal thermometer, infrared auricular thermometer, and microchip, core body temperature was measured via a thermistor-tipped pulmonary artery (TTPA) catheter. Hypothermia was induced during anesthesia at the time of TTPA catheter placement; on 3 occasions after placement of the catheter, hyperthermia was induced via administration of a low dose of endotoxin. Near-simultaneous duplicate temperature measurements were recorded from the TTPA catheter, the rectal thermometer, auricular thermometer, and subcutaneous microchips during hypothermia, euthermia, and hyperthermia. Reliability (variability) of temperature measurement for each device and agreement between each device measurement and core body temperature were assessed. Results —Variability between duplicate near-simultaneous temperature measurements was greatest for the auricular thermometer and least for the TTPA catheter. Measurements obtained by use of the rectal thermometer were in closest agreement with core body temperature; for all other devices, temperature readings typically underestimated core body temperature. Conclusions and Clinical Relevance —Among the 3 methods of temperature measurement, rectal thermometry provided the most accurate estimation of core body temperature in dogs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Rectal thermometry is regarded as an acceptable method for estimating core body temperature, 10 although stress or physical exertion may potentially increase this parameter.11”
From Evaluation of the Effects of Hospital Visit Stress on Physiologic Parameters in the Cat (2011) · cites this paper as [10]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Subcutaneous adipose tissue thickness alters cooling time during cryotherapy
Otte, J. W., Merrick, M. A., Ingersoll, C. D., & Cordova, M. L. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.34833 · Cited by 143
Core temperature measurement in the intensive care unit
Nierman, D. M. (1991) · Critical Care Medicine · doi:10.1097/00003246-199106000-00015 · Cited by 94
Dodd, S. R., Lancaster, G. A., Craig, J. V., Smyth, R. L., & Williamson, P. R. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.10.004 · Cited by 90
Heteroepitaxial growth and characterization of InP on Si substrates
Sugo, M., Takanashi, Y., Al‐Jassim, M. M., & Yamaguchi, M. (1990) · Journal of Applied Physics · doi:10.1063/1.346826 · Cited by 78
Chen, P. H., & White, C. E. (2006) · PubMed · Cited by 74
Monitoring Urinary Bladder Temperature in the Intensive Care Unit: State of the Science
Fallis, W. M. (2002) · American Journal of Critical Care · doi:10.4037/ajcc2002.11.1.38 · Cited by 68
Kunkle, G. A., Nicklin, C. F., & Sullivan-Tamboe, D. L. (2004) · Journal of the American Animal Hospital Association · doi:10.5326/0400042 · Cited by 55
Cited by
Evaluation of the Effects of Hospital Visit Stress on Physiologic Parameters in the Cat
Quimby, J. M., Smith, M. L., & Lunn, K. F. (2011) · Journal of Feline Medicine and Surgery · doi:10.1016/j.jfms.2011.07.003 · Cited by 203
Metadata
- Authors
- Greer, R. J., Cohn, L. A., Dodam, J. R., Wagner-Mann, C. C., & Mann, F. A.
- Affiliations
- University of Missouri (US)
- Venue
- Journal of the American Veterinary Medical Association
- Published
- 2007-06-15
- Volume
- 230
- Issue
- 12
- Pages
- 1841-1848
- ISSN
- 0003-1488 (ISSN-L)
- OpenAlex
- W2040550987
- Cited by
- 101
- References
- 27
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 3 · 2023: 10 · 2022: 5 · 2021: 5 · 2020: 5 · 2019: 9 · 2018: 2 · 2017: 10 · 2016: 9 · 2015: 8 · 2014: 5 · 2013: 3 · 2012: 4
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of the American Veterinary Medical Association (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
- Health Sciences › Veterinary › Small Animals › Veterinary Medicine and Surgery
- Health Sciences › Veterinary › Small Animals › Veterinary Pharmacology and Anesthesia
- Keywords
- core body temperature, temperature measurement, rectal thermometry, hypothermia, hyperthermia, dogs, measurement reliability, measurement accuracy
- MeSH terms
- Animals, Body Temperature, Catheterization, Swan-Ganz, Dogs, Ear, Female, Fever, Hypothermia, Male, Prospective Studies, Pulmonary Artery, Rectum, Sensitivity and Specificity, Thermometers, Cross-Over Studies, Microchip Analytical Procedures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of three methods of temperature measurement in hypothermic, euthermic, and hyperthermic dogs. https://app.cochat.ai/papers/10.2460/javma.230.12.1841
- The paper
- Greer, R. J., Cohn, L. A., Dodam, J. R., Wagner-Mann, C. C., & Mann, F. A. (2007). Comparison of three methods of temperature measurement in hypothermic, euthermic, and hyperthermic dogs. Journal of the American Veterinary Medical Association. https://doi.org/10.2460/javma.230.12.1841
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.