The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Application of Wavelet Analysis in EMG Feature Extraction for Pattern Classification
Open accessAbstract
Nowadays, analysis of electromyography (EMG) signal using wavelet transform is one of the most powerful signal processing tools. It is widely used in the EMG recognition system. In this study, we have investigated usefulness of extraction of the EMG features from multiple-level wavelet decomposition of the EMG signal. Different levels of various mother wavelets were used to obtain the useful resolution components from the EMG signal. Optimal EMG resolution component (sub-signal) was selected and then the reconstruction of the useful information signal was done. Noise and unwanted EMG parts were eliminated throughout this process. The estimated EMG signal that is an effective EMG part was extracted with the popular features, i.e. mean absolute value and root mean square, in order to improve quality of class separability. Two criteria used in the evaluation are the ratio of a Euclidean distance to a standard deviation and the scatter graph. The results show that only the EMG features extracted from reconstructed EMG signals of the first-level and the second-level detail coefficients yield the improvement of class separability in feature space. It will ensure that the result of pattern classification accuracy will be as high as possible. Optimal wavelet decomposition is obtained using the seventh order of Daubechies wavelet and the forth-level wavelet decomposition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
Cited by
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Lu, Z., Chen, X., Li, Q., Zhang, X., & Zhou, P. (2014) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2014.2302794 · Cited by 294
Wavelet Analysis: Mother Wavelet Selection Methods
Ngui, W. K., Leong, M. S., Hee, L. M., & Abdelrhman, A. M. (2013) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.393.953 · Cited by 273
Real-Time Surface EMG Pattern Recognition for Hand Gestures Based on an Artificial Neural Network
Zhang, Z., Yang, K., Qian, J., & Zhang, L. (2019) · Sensors · doi:10.3390/s19143170 · Cited by 165
Metadata
- Authors
- Phinyomark, A., Limsakul, C., & Phukpattaranont, P.
- Venue
- Measurement Science Review
- Publisher
- Walter de Gruyter GmbH
- Published
- 2011-01-01
- Volume
- 11
- Issue
- 2
- ISSN
- 1335-8871 (ISSN-L)
- OpenAlex
- W2062715730
- Cited by
- 236
- References
- 2
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of Wavelet Analysis in EMG Feature Extraction for Pattern Classification. https://app.cochat.ai/papers/10.2478/v10048-011-0009-y
- The paper
- Phinyomark, A., Limsakul, C., & Phukpattaranont, P. (2011). Application of Wavelet Analysis in EMG Feature Extraction for Pattern Classification. Measurement Science Review. https://doi.org/10.2478/v10048-011-0009-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.