Operating characteristics of transcritical CO2 heat pump for simultaneous water cooling and heating
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The effects of water-side operating conditions (mass flow rates and inlet temperatures) of both evaporator and gas cooler on the experimental as well as simulated performances (cooling and heating capacities, system coefficient of performance (COP) and water outlet temperatures) of the transcritical CO2 heat pump for simultaneous water cooling and heating the are studied and revised. Study shows that both the water mass flow rate and inlet temperature have significant effect on the system performances. Test results show that the effect of evaporator water mass flow rate on the system performances and water outlet temperatures is more pronounced (COP increases by 0.6 for 1 kg/min) compared to that of gas cooler water mass flow rate (COP increases by 0.4 for 1 kg/min) and the effect of gas cooler water inlet temperature is more significant (COP decreases by 0.48 for given range) compared to that of evaporator water inlet temperature (COP increases by 0.43 for given range). Comparisons of experimental values with simulated results show the maximum deviation of 5% for cooling capacity, 10% for heating capacity and 16% for system COP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamental process and system design issues in CO2 vapor compression systems
Kim, M. (2004) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2003.09.002 · Cited by 735
Sarkar, J., Bhattacharyya, S., & Gopal, M. R. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2004.03.006 · Cited by 393
Self-citationCO2-heat pump water heater: characteristics, system design and experimental results
Nekså, P., Rekstad, H., Zakeri, G. R., & Schiefloe, P. A. (1998) · International Journal of Refrigeration · doi:10.1016/s0140-7007(98)00017-6 · Cited by 378
Nekså, P. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(01)00033-0 · Cited by 324
Transcritical carbon dioxide heat pump systems: A review
Austin, B. T., & Sumathy, K. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.07.021 · Cited by 277 · cited 1×
“After that work, most of the works published on CO2 heat pumps within 2000s are mainly for heating applications [3].”
BackgroundYoon, S. H., Cho, E. S., Hwang, Y. W., Kim, M. S., Min, K., & Kim, Y. (2004) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2003.08.006 · Cited by 160 · cited 1×
“[19] correlation has been employed to estimate the boiling heat transfer coefficient.”
MethodSimulation of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications
Sarkar, J., Bhattacharyya, S., & Gopal, M. (2006) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2005.12.006 · Cited by 136 · cited 3×
“It may be noted that the mass flow rate of refrigerant is nearly invariant with the water mass flow rates and water inlet temperatures due to conditions applied (constant suction and discharge pressures, dissimilar to the earlier study [9]) in the present case.”
BackgroundMethodResultInfluentialSelf-citationByrne, P., Miriel, J., & Lénat, Y. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.05.008 · Cited by 117 · cited 1×
“[14] studied CO2 heat pump for space cooling and heating.”
BackgroundBhattacharyya, S., Garai, A., & Sarkar, J. (2008) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.09.008 · Cited by 94 · cited 1×
“[13] studied CO2 cascade system for refrigeration and heating.”
BackgroundSelf-citationGoodman, C., Fronk, B. M., & Garimella, S. (2010) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2010.12.001 · Cited by 15 · cited 1×
“Similar trend has been observed with internal heat exchanger also [21].”
Background
Cited by
Solar process heat in industrial systems – A global review
Farjana, S. H., Huda, N., Mahmud, M. A. P., & Saidur, R. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.08.065 · Cited by 269
Electrochemical Hydrogen Production: Sustainable Hydrogen Economy
Aslam, S., Rani, S., Lal, K., Fatima, M., Hardwick, T., Shirinfar, B., & Ahmed, N. (2023) · Green Chemistry · doi:10.1039/d3gc02849f · Cited by 263
Navigating challenges in large-scale renewable energy storage: Barriers, solutions, and innovations
Jafarizadeh, H., Yamini, E., Zolfaghari, S. M., Esmaeilion, F., Assad, M. E. H., & Soltani, M. (2024) · Energy Reports · doi:10.1016/j.egyr.2024.08.019 · Cited by 261
Rahman, T., & Alharbi, T. (2024) · Batteries · doi:10.3390/batteries10070220 · Cited by 200
Bibin, C., Vijayaram, M., Suriya, V., Sai Ganesh, R., & Soundarraj, S. (2020) · Materials Today: Proceedings · doi:10.1016/j.matpr.2020.03.317 · Cited by 197
Alsharif, A., Tan, C. W., Ayop, R., Dobi, A., & Lau, K. Y. (2021) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2021.101439 · Cited by 182
Mohammad, A., Zamora, R., & Lie, T. T. (2020) · Energies · doi:10.3390/en13174541 · Cited by 170
“A case study presented in Reference [58] compares charging of EVs through the modes: Only grid, only PV with battery storage and grid integrated PV and finds that the grid integrated PV performs better economically compared to the other two systems.”
Background
Metadata
- Authors
- Sarkar, J., & Bhattacharyya, S.
- Venue
- Archives of Thermodynamics
- Published
- 2011-11-01
- Volume
- 33
- Issue
- 4
- Pages
- 23-40
- ISSN
- 1231-0956 (ISSN-L)
- 2083-6023
- OpenAlex
- W2035290804
- Cited by
- 236
- References
- 10
- FWCI
- 0.57
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.