Empirical approach to outdoor WBGT from meteorological data and performance of two different instrument designs
Open accessAbstract
The wet bulb globe temperature index (WBGT) is a common method to assess the environmental contribution to heat stress as part of an occupational exposure assessment. The two purposes of this study were (1) to compare empirical relationships of some meteorological conditions to WBGT, and (2) to evaluate a smaller globe and alternative method to assess natural wet bulb using a relative humidity sensor. Data were collected in six West-central Florida locations over multiple days for a total of 14 measurement days. Multiple linear regression was used to explore relationships relevant to the two purposes. It was clear that estimating WBGT directly from meteorological data or through estimates of the components of WBGT can be accomplished with a 95% confidence of ± 2°C-WBGT. The 50 mm globe size is a reasonable approximation of the standard size (150 mm). The relative humidity method of the waterless natural wet bulb provides a very good estimation of natural wet bulb temperature. The determination of WBGT from the electronic instruments (small globe with or without the relative humidity method) provided a good estimate of the WBGT.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The two WBGT instruments (QUESTemp44 and Kestrel5400) were validated to measure WBGT and used in heat stress exposure research.
“These instruments were validated to measure WBGT and used in heat stress exposure research (Bernard and Barrow, 2013; Cheuvront et al., 2015).”
From Assessment of Heat Stress Exposure among Construction Workers in the Hot Desert Climate of Saudi Arabia (2019) · cites this paper as Bernard and Barrow, 2013
Cites
Modeling the Wet Bulb Globe Temperature Using Standard Meteorological Measurements
Liljegren, J. C., Carhart, R. A., Lawday, P., Tschopp, S., & Sharp, R. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802310770 · Cited by 404 · see citing works
Calculating Workplace WBGT from Meteorological Data: A Tool for Climate Change Assessment
LEMKE, B., & KJELLSTROM, T. (2012) · Industrial Health · doi:10.2486/indhealth.ms1352 · Cited by 394 · see citing works
Prediction of Workplace Wet Bulb Global Temperature
Bernard, T. E. (1999) · Applied Occupational and Environmental Hygiene · doi:10.1080/104732299303296 · Cited by 128 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Al-Bouwarthan, M., Quinn, M. M., Kriebel, D., & Wegman, D. H. (2019) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxz033 · Cited by 144 · see citing works
Climatic and psychosocial risks of heat illness incidents on construction site
Jia, Y. A., Rowlinson, S., & Ciccarelli, M. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.08.008 · Cited by 70 · see citing works
- Authors
- BERNARD, T. E., & BARROW, C. A.
- Affiliations
- University of South Florida (US)
- ORCID
- BERNARD, Thomas E.
- Venue
- Industrial Health
- Published
- 2013
- Volume
- 51
- Issue
- 1
- Pages
- 79-85
- ISSN
- 0019-8366 (ISSN-L)
- 1880-8026
- OpenAlex
- W1983580543
- Cited by
- 33
- References
- 3
- Citations by year
- 2026: 1 · 2024: 2 · 2023: 1 · 2021: 4 · 2020: 2 · 2019: 5 · 2017: 5 · 2016: 3 · 2015: 5 · 2014: 2 · 2013: 3
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Industrial Health (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Centers for Disease Control and Prevention (T42OH008438)
- National Institute for Occupational Safety and Health (T42 OH 008438)
- Topics
- Health Sciences › Medicine › Physiology › Thermoregulation and physiological responses
- Health Sciences › Health Professions › Occupational Therapy › Occupational Health and Safety in Workplaces
- Physical Sciences › Environmental Science › Environmental Engineering › Urban Heat Island Mitigation
- Keywords
- wet bulb globe temperature, heat stress, occupational exposure assessment, weather conditions, relative humidity sensor
- MeSH terms
- Environmental Monitoring, Florida, Hot Temperature, Humans, Meteorological Concepts, Occupational Exposure, Heat Stress Disorders
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review