CoChat

Objective Assessment of the Breathe-Right Device during Exercise in Adult Males

Portugal, Louis G., Mehta, Rajeev H., Smith, Bonnie E., Sabnani, Jaishiri B., Matava, Matthew J. · 1997 · American Journal of Rhinology
Cited by 40

The DOI matches its Crossref record.

Abstract

In order to improve nasal breathing during competition, many athletes recently have been wearing a spring-loaded, external nasal dilator referred to as the Breathe-Right device (BRD). Although there are many subjective claims that this device improves breathing during exercise, there are currently no controlled studies documenting its efficacy. To determine objectively whether the device improves the nasal airway, 20 subjects (10 Caucasian and 10 African-American) were studied during rest and after 15 minutes of exercise using anterior rhinomanometry and acoustic rhinometry to measure changes in airway resistance and minimal cross-sectional area, respectively. We found that the BRD exerts its main effect in the region of the nasal valve improving the airway an overall 21% in our group of subjects. This anatomic improvement in nasal airway resulted in an overall 27% reduction in nasal resistance in the Caucasian group. However, in the African-American group, a wider range of resistance changes was observed with application of the BRD with significant improvement in nasal resistance in some subjects but paradoxical worsening in others. In the African-American group as a whole, no significant change in nasal resistance occured with application of the BRD. These measured differences are likely due to variations in nasal anatomy that exist not only between races but also between individuals within a given race. In addition, this study confirms the well known decongestant effects of exercise providing anatomic data with acoustic rhinometry not previously documented in the literature. Overall improvement in nasal airway seen with application of the BRD occured independent of these exercise-related decongestant effects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2500/105065897781286061

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 40

Metadata

Authors
Portugal, L. G., Mehta, R. H., Smith, B. E., Sabnani, J. B., & Matava, M. J.
Venue
American Journal of Rhinology
Published
1997-09
Volume
11
Issue
5
Pages
393-398
ISSN
  • 1050-6586 (ISSN-L)
  • 1539-6290
OpenAlex
W2088370827
Cited by
40
References
0
FWCI
2.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Objective Assessment of the Breathe-Right Device during Exercise in Adult Males. https://app.cochat.ai/papers/10.2500/105065897781286061
The paper
Portugal, L. G., Mehta, R. H., Smith, B. E., Sabnani, J. B., & Matava, M. J. (1997). Objective Assessment of the Breathe-Right Device during Exercise in Adult Males. American Journal of Rhinology. https://doi.org/10.2500/105065897781286061

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.