Test-Retest Reliability and Minimal Detectable Change on Balance and Ambulation Tests, the 36-Item Short-Form Health Survey, and the Unified Parkinson Disease Rating Scale in People With Parkinsonism
Abstract
Background and Purpose: Distinguishing between a clinically significant change and change due to measurement error can be difficult. The purpose of this study was to determine test-retest reliability and minimal detectable change for the Berg Balance Scale (BBS), forward and backward functional reach, the Romberg Test and the Sharpened Romberg Test (SRT) with eyes open and closed, the Activities-specific Balance Confidence (ABC) Scale, the Six-Minute Walk Test (6MWT), comfortable and fast gait speed, the Timed “Up & Go” Test (TUG), the Medical Outcomes Study 36-Item Short-Form Health Survey (SF-36), and the Unified Parkinson Disease Rating Scale (UPDRS) in people with parkinsonism. Subjects: Thirty-seven community-dwelling adults with parkinsonism (mean age=71 years) participated. The Hoehn and Yahr Scale median score of 2 was on the lower end of the scale; however, the scores ranged from 1 to 4. Methods: Subjects were tested twice by the same raters, with 1 week between tests. Test-retest reliability was calculated using intraclass correlation coefficients (ICCs). Minimal detectable change was calculated using a 95% confidence interval (MDC95). Results: The ICCs for test-retest reliability were above .90 for the BBS, ABC Scale, SRT with eyes closed, 6MWT, and comfortable and fast gait speeds. The MDC95 values for those functional tests were: BBS=5/56, ABC Scale=13%, SRT with eyes closed=19 seconds, 6MWT=82 m, comfortable gait speed=0.18 m/s, and fast gait speed=0.25 m/s. The ICCs for test-retest reliability of SF-36 scores were above .80, with the exception of the social functioning subscale. The MDC95 values for the SF-36 ranged between 19% and 45%. The MDC95 values for the UPDRS Activities of Daily Living section, Motor Examination section, and total scores were 4/52, 11/108, and 13/176, respectively. Discussion and Conclusion: Minimal detectable change values are useful to therapists in rehabilitation and wellness programs in determining whether change during or after intervention is clinically significant. High test-retest reliability of scores for the BBS, ABC Scale, SRT with eyes closed, 6MWT, and gait speed make them trustworthy functional assessments in people with parkinsonism. The SF-36 and UPDRS provide quality-of-life and disease severity rating values in the ongoing assessment of people with parkinsonism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons
Podsiadlo, D., & Richardson, S. (1991) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1991.tb01616.x · Cited by 14,418
Parkinsonism: onset, progression, and mortality
Hoehn, M. M., & Yahr, M. D. (1967) · Neurology · doi:10.1212/wnl.17.5.427 · Cited by 12,107
ATS Statement: Guidelines for the Six-Minute Walk Test
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.166.1.at1102 · Cited by 11,195
Redelmeier, D. A., Bayoumi, A. M., Goldstein, R. S., & Guyatt, G. H. (1997) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.155.4.9105067 · Cited by 1,029
Reliability of four simple, quantitative tests of balance and mobility in healthy elderly females
Franchignoni, F., Tesio, L., Martino, M. T., & Ricupero, C. (1998) · Aging Clinical and Experimental Research · doi:10.1007/bf03339630 · Cited by 217
Cited by
Long-term effects of exercise and physical therapy in people with Parkinson disease
Mak, M. K., Wong-Yu, I. S., Shen, X., & Chung, C. L. (2017) · Nature Reviews Neurology · doi:10.1038/nrneurol.2017.128 · Cited by 549
Physiotherapy versus placebo or no intervention in Parkinson's disease
Tomlinson, C. L., Patel, S., Meek, C., Herd, C. P., Clarke, C. E., Stowe, R., Shah, L., Sackley, C. M., Deane, K. H., Wheatley, K., et al. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002817.pub4 · Cited by 441
Godi, M., Franchignoni, F., Caligari, M., Giordano, A., Turcato, A. M., & Nardone, A. (2013) · Physical Therapy · doi:10.2522/ptj.20120171 · Cited by 438
Huang, S.-L., Hsieh, C.-L., Wu, R.-M., Tai, C.-H., Lin, C.-H., & Lu, W.-S. (2011) · Physical Therapy · doi:10.2522/ptj.20090126 · Cited by 401
Kwok, J. Y. Y., Kwan, J. C. Y., Auyeung, M., Mok, V. C. T., Lau, C. K. Y., Choi, K. C., & Chan, H. Y. L. (2019) · JAMA Neurology · doi:10.1001/jamaneurol.2019.0534 · Cited by 379
Metadata
- Authors
- Steffen, T., & Seney, M.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-06-01
- Volume
- 88
- Issue
- 6
- Pages
- 733-746
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2166232227
- Cited by
- 860
- References
- 5
- FWCI
- 66.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Test-Retest Reliability and Minimal Detectable Change on Balance and Ambulation Tests, the 36-Item Short-Form Health Survey, and the Unified Parkinson Disease Rating Scale in People With Parkinsonism. https://app.cochat.ai/papers/10.2522/ptj.20070214
- The paper
- Steffen, T., & Seney, M. (2008). Test-Retest Reliability and Minimal Detectable Change on Balance and Ambulation Tests, the 36-Item Short-Form Health Survey, and the Unified Parkinson Disease Rating Scale in People With Parkinsonism. Physical Therapy. https://doi.org/10.2522/ptj.20070214
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.