Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 252

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Psychometric Comparisons of 4 Measures for Assessing Upper-Extremity Function in People With Stroke

Lin, Jau-Hong, Hsu, Miao-Ju, Sheu, Ching-Fan, Wu, Tzung-Shian, Lin, Ruey-Tay, Chen, Chia-Hsin, Hsieh, Ching-Lin·2009·Physical Therapy

Abstract

Background: Functional limitation of the upper extremities is common in patients with stroke. An upper-extremity measure with sound psychometric properties is indispensable for clinical and research use. Objective: The purpose of this study was to compare the psychometric properties of 4 clinical measures for assessing upper-extremity motor function in people with stroke: the upper-extremity subscale of the Fugl-Meyer Motor Test (UE-FM), the upper-extremity subscale of the Stroke Rehabilitation Assessment of Movement, the Action Research Arm Test (ARAT), and the Wolf Motor Function Test. Design: This was a prospective, longitudinal study. Methods: Fifty-three people with stroke were evaluated with the 4 measures at 4 time points (14, 30, 90, and 180 days after stroke). Thirty-five participants completed all of the assessments. The ceiling and floor effects, validity (concurrent validity and predictive validity), and responsiveness of each measure were examined. Interrater reliability and test-retest reliability also were examined. Results: All measures, except for the UE-FM, had significant floor effects or ceiling effects at one or more time points. The Spearman ρ correlation coefficient for each pair of the 4 measures was ≥.81, indicating high concurrent validity. The predictive validity of the 4 measures was satisfactory (Spearman ρ, ≥.51). The responsiveness of the 4 measures at 14 to 180 days after stroke was moderate (.52 ≤ effect size ≤ .79). The 4 measures had good interrater reliability (intraclass correlation coefficient [ICC], ≥.92) and test-retest reliability (ICC, ≥.97). Only the minimal detectable changes of the UE-FM (8% of the highest possible score) and the ARAT (6%) were satisfactory. Limitations: The sample size was too small to conduct data analysis according to type or severity of stroke. In addition, the timed component of the Wolf Motor Function Test was not used in this study. Conclusions: All 4 measures showed sufficient validity, responsiveness, and reliability in participants with stroke. The UE-FM for assessing impairment and the ARAT for assessing disability had satisfactory minimal detectable changes, supporting their utility in clinical settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2522/ptj.20080285

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 252

Metadata

Authors
Lin, J.-H., Hsu, M.-J., Sheu, C.-F., Wu, T.-S., Lin, R.-T., Chen, C.-H., & Hsieh, C.-L.
Venue
Physical Therapy
Published
2009-08-01
Volume
89
Issue
8
Pages
840-850
ISSN
  • 0031-9023 (ISSN-L)
  • 1538-6724
OpenAlex
W2136757261
Cited by
252
References
1
FWCI
10.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Psychometric Comparisons of 4 Measures for Assessing Upper-Extremity Function in People With Stroke. https://app.cochat.ai/papers/10.2522/ptj.20080285
The paper
Lin, J.-H., Hsu, M.-J., Sheu, C.-F., Wu, T.-S., Lin, R.-T., Chen, C.-H., & Hsieh, C.-L. (2009). Psychometric Comparisons of 4 Measures for Assessing Upper-Extremity Function in People With Stroke. Physical Therapy. https://doi.org/10.2522/ptj.20080285

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.