Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 281

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Reliability of Outcome Measures for People With Lower-Limb Amputations: Distinguishing True Change From Statistical Error

Open access
Resnik, Linda, Borgia, Matthew·2011·Physical Therapy

Abstract

BACKGROUND: Use of outcome measures to examine outcomes of amputation is complicated by a number of factors, including ease of administration and lack of scientific evidence to guide selection and interpretation. OBJECTIVE: The purposes of this study were: (1) to estimate test-retest reliability of a modified version of the Prosthetic Evaluation Questionnaire (PEQ), scales of a version of the 36-Item Short-Form Health Survey questionnaire adapted for the veteran population (SF-36V), the Orthotics and Prosthetics Users' Survey (OPUS), the Patient-Specific Functional Scale (PSFS), the Two-Minute Walk Test, the Six-Minute Walk Test, the Timed "Up & Go" Test, and the Amputee Mobility Predictor; (2) to calculate minimal detectable change (MDC) of each measure; and (3) to conduct item analysis of the modified PEQ. DESIGN: This was a multi-site study with repeated measurements. METHODS: Forty-four patients with unilateral lower-limb amputation participated. Participants were tested twice within 1 week. We calculated test-retest reliability of each measure using intraclass correlation coefficient (ICC [2,1]), estimated standard error of the measurement and MDC, and assessed scale score distribution. RESULTS: The study demonstrated strong test-retest reliability scores of performance measures (ICC=.83-.97) suggesting that these measures are good choices for evaluation of people with lower-limb amputation. Reliability of PEQ subscales (ICC=.41-.93) was comparable to that reported in the literature (ICC=.56-.90). LIMITATIONS: This study examined only statistically measurable differences and did not evaluate whether changes in scores were clinically important. CONCLUSIONS: Minimal detectable change scores can be used to determine whether change in test scores exceeds measurement error associated with day-to-day variation. This is the first study to present test-retest reliability data on the self-reported OPUS scales, the PSFS in people with lower-limb amputations, and a new, easier-to-use scoring mechanism for the PEQ.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2522/ptj.20100287

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Cited by

See all 281

Metadata

Authors
Resnik, L., & Borgia, M.
Venue
Physical Therapy
Published
2011-04-01
Volume
91
Issue
4
Pages
555-565
ISSN
  • 0031-9023 (ISSN-L)
  • 1538-6724
OpenAlex
W2130253279
Cited by
281
References
46
FWCI
30.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of Outcome Measures for People With Lower-Limb Amputations: Distinguishing True Change From Statistical Error. https://app.cochat.ai/papers/10.2522/ptj.20100287
The paper
Resnik, L., & Borgia, M. (2011). Reliability of Outcome Measures for People With Lower-Limb Amputations: Distinguishing True Change From Statistical Error. Physical Therapy. https://doi.org/10.2522/ptj.20100287

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.