CoChat

Reliability and Responsiveness of the Gross Motor Function Measure-88 in Children With Cerebral Palsy

Ko, Jooyeon, Kim, MinYoung · 2013 · Physical Therapy
Cited by 187

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

Background: The Gross Motor Function Measure (GMFM-88) is commonly used in the evaluation of gross motor function in children with cerebral palsy (CP). The relative reliability of GMFM-88 has been assessed in children with CP. However, little information is available regarding the absolute reliability or responsiveness of GMFM-88. Objective: The purpose of this study was to determine the absolute and relative reliability and the responsiveness of the GMFM-88 in evaluating gross motor function in children with CP. Design: A clinical measurement design was used. Methods: Ten raters scored the GMFM-88 in 84 children (mean age=3.7 years, SD=1.9, range=10 months to 9 years 9 months) from video records across all Gross Motor Function Classification System (GMFCS) levels to establish interrater reliability. Two raters participated to assess intrarater reliability. Responsiveness was determined from 3 additional assessments after the baseline assessment. The interrater and intrarater intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement (SEM), smallest real difference (SRD), effect size (ES), and standardized response mean (SRM) were calculated. Results: The relative reliability of the GMFM was excellent (ICCs=.952–1.000). The SEM and SRD for total score of the GMFM were acceptable (1.60 and 3.14, respectively). Additionally, the ES and SRM of the dimension goal scores increased gradually in the 3 follow-up assessments (GMFCS levels I and II: ES=0.5, 0.6, and 0.8 and SRM=1.3, 1.8, and 2.0; GMFCS levels III–V: ES=0.4, 0.7, and 0.9 and SRM=1.5, 1.7, and 2.0). Limitations: Children over 10 years of age with CP were not included in this study, so the results should not be generalized to all children with CP. Conclusions: Both the reliability and the responsiveness of the GMFM-88 are reasonable for measuring gross motor function in children with CP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2522/ptj.20110374

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Metadata

Authors
Ko, J., & Kim, M.
Venue
Physical Therapy
Published
2013-03-01
Volume
93
Issue
3
Pages
393-400
ISSN
  • 0031-9023 (ISSN-L)
  • 1538-6724
OpenAlex
W2127332873
Cited by
187
References
32
FWCI
3.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability and Responsiveness of the Gross Motor Function Measure-88 in Children With Cerebral Palsy. https://app.cochat.ai/papers/10.2522/ptj.20110374
The paper
Ko, J., & Kim, M. (2013). Reliability and Responsiveness of the Gross Motor Function Measure-88 in Children With Cerebral Palsy. Physical Therapy. https://doi.org/10.2522/ptj.20110374

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.