Hausmann, D., Dinter, D. J., Sadick, M., Brade, J., Schoenberg, S. O., Busing, K.·2012·Journal of Nuclear Medicine Technology

Abstract

UNLABELLED: Our objective was to evaluate the impact of acquisition time on image quality, lesion detection rate, standardized uptake values, and lesion volume for (18)F-FDG PET in cancer patients. METHODS: Over 7 mo, 33 cancer patients were included in this study. In these patients, 63 lesions were independently evaluated by 2 nuclear medicine specialists (experienced and beginner). Two consecutive whole-body (18)F-FDG PET/CT scans using a 3-min and 1.5-min acquisition time per bed position were obtained for each patient. Lesions were visually identified, and their locations were compared. The lesion volumes and standardized uptake values of the primary tumor, lymph nodes, and metastases were determined and compared. Image quality was scored using a 5-range Likert-type scale. For all parameters, interobserver agreement was assessed. RESULTS: All relevant lesions could be identified at both acquisition times. Image quality was slightly adversely affected by an acquisition time of 1.5 min but was excellent or good in 85% of the scans. In a patient with increased blood sugar levels, the image quality was rated moderate at 3 min and poor at 1.5 min. The quality of lesion visualization was excellent regardless of the acquisition time. Lesion volume and maximum standardized uptake value on PET images showed an excellent correlation between the 2 acquisition times (Pearson correlation coefficient, 0.99 and 0.97, respectively). Interobserver agreement was excellent (κ > 0.83). CONCLUSION: Although image quality is slightly poorer, reducing the acquisition time to 1.5 min per bed position seems to be clinically feasible without decreasing the lesion detection rate even for less experienced observers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnmt.112.103291

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 21

Metadata

Authors
Hausmann, D., Dinter, D. J., Sadick, M., Brade, J., Schoenberg, S. O., & Busing, K.
Affiliations
Heidelberg University (DE)
Venue
Journal of Nuclear Medicine Technology
Published
2012-10-15
Volume
40
Issue
4
Pages
255-258
ISSN
0091-4916 (ISSN-L)
OpenAlex
W2170056898
Cited by
21
References
13
Citations by year
2025: 1 · 2024: 1 · 2023: 3 · 2022: 4 · 2020: 3 · 2019: 1 · 2017: 1 · 2016: 2 · 2015: 3 · 2013: 2
FWCI
1.20
Type
journal article
Language
en
Open access
Locations
  • Journal of Nuclear Medicine Technology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
Keywords
18F-FDG PET/CT, acquisition time, whole-body imaging, tumor staging, image quality, lesion detection rate, standardized uptake value, lesion volume, interobserver agreement, blood glucose, scan time reduction
MeSH terms
Adult, Aged, Aged, 80 and over, Feasibility Studies, Female, Humans, Male, Middle Aged, Neoplasm Staging, Neoplasms, Quality Control, Time Factors, Tomography, X-Ray Computed, Observer Variation, Fluorodeoxyglucose F18, Tumor Burden, Positron-Emission Tomography, Whole Body Imaging, Multimodal Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.