Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 418

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

A Novel Method of 18F Radiolabeling for PET

Open access
McBride, William J., Sharkey, Robert M., Karacay, Habibe, D'Souza, Christopher A., Rossi, Edmund A., Laverman, Peter, Chang, Chien-Hsing, Boerman, Otto C., Goldenberg, David M.·2009·Journal of Nuclear Medicine

Abstract

UNLABELLED: Small biomolecules are typically radiolabeled with (18)F by binding it to a carbon atom, a process that usually is designed uniquely for each new molecule and requires several steps and hours to produce. We report a facile method wherein (18)F is first attached to aluminum as Al(18)F, which is then bound to a chelate attached to a peptide, forming a stable Al(18)F-chelate-peptide complex in an efficient 1-pot process. METHODS: For proof of principle, this method was applied to a peptide suitable for use in a bispecific antibody pretargeting method. A solution of AlCl(3).6H(2)O in a pH 4.0 sodium-acetate buffer was mixed with an aqueous solution of (18)F to form the Al(18)F complex. This was added to a solution of IMP 449 (NOTA-p-Bn-CS-d-Ala-d-Lys(HSG)-d-Tyr-d-Lys(HSG)-NH(2)) (NOTA-p-Bn-CS is made from S-2-(4-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid; HSG is histamine-succinyl-glycine) and heated to 100 degrees C for 15 min. In vitro and in vivo stability and targeting ability of the Al(18)F-IMP 449 were examined in nude mice bearing LS174T human colonic tumors pretargeted with an anti-CEACAM5 bispecific antibody (TF2). RESULTS: The radiolabeled peptide was produced in 5%-20% yield with an estimated specific activity of 18,500-48,100 GBq (500-1,300 Ci)/mmol. The Al(18)F-IMP 449 was stable for 4 h in serum in vitro, and in animals, activity isolated in the urine 30 min after injection was bound to the peptide. Nonchelated Al(18)F had higher tissue uptake, particularly in the bones, than the chelated Al(18)F-IMP 449, which cleared rapidly from the body by urinary excretion. Tumor uptake was 30-fold higher with TF2-pretargeted Al(18)F-IMP 449 than with the peptide alone. Dynamic PET showed tumor localization within 30 min and rapid and thorough clearance from the body. CONCLUSION: The ability to bind highly stable Al(18)F to metal-binding ligands is a promising new labeling method that should be applicable to a diverse array of molecules for PET.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.108.060418

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 418

Metadata

Authors
McBride, W. J., Sharkey, R. M., Karacay, H., D'Souza, C. A., Rossi, E. A., Laverman, P., Chang, C.-H., Boerman, O. C., & Goldenberg, D. M.
Venue
Journal of Nuclear Medicine
Published
2009-05-14
Volume
50
Issue
6
Pages
991-998
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2032643964
Cited by
418
References
18
FWCI
17.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Method of 18F Radiolabeling for PET. https://app.cochat.ai/papers/10.2967/jnumed.108.060418
The paper
McBride, W. J., Sharkey, R. M., Karacay, H., D'Souza, C. A., Rossi, E. A., Laverman, P., Chang, C.-H., Boerman, O. C., & Goldenberg, D. M. (2009). A Novel Method of 18F Radiolabeling for PET. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.108.060418

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.