NEMA NU4-2008 Image Quality Performance Report for the microPET Focus 120 and for Various Transmission and Reconstruction Methods
Open accessThe DOI matches its Crossref record.
Abstract
UNLABELLED: This work aimed to evaluate the image quality and accuracy of attenuation and scatter corrections provided with the microPET Focus 120 scanner using the National Electrical Manufacturers Association NU4-2008 image quality phantom. METHODS: Attenuation correction was obtained from transmission measurements using either a (68)Ge or a (57)Co point source. Fully corrected emission images were reconstructed using Fourier rebinning (FORE) and filtered backprojection (FBP). For attenuation data obtained with the (57)Co source, fully corrected emission images were also reconstructed using FORE and 2-dimensional (2D) ordered-subset expectation maximization (OSEM), 3-dimensional (3D) filtered backprojection (3DRP), 3D OSEM, and 3D maximum a posteriori methods. The mean activity, the coefficients of variation (COVs) of the uniform slices, the recovery coefficients (RCs) for hot rods, and the spillover ratio (SOR) for nonemitting water and air compartments were measured. RESULTS: For (57)Co-based attenuation correction, the mean activity value differed by less than 3% from the true activity. Measuring the attenuation with (68)Ge resulted in lower reconstructed activity and higher COV. On the basis of (57)Co measurements, the SORs for air and water nonemitting compartments were the closest to zero for attenuation correction. The RC measured on emission images corrected for attenuation but not for scatter did not show any significant difference linked to the transmission method. However, higher RCs were noted for transmission measurement with (68)Ge in coincidence with windowing when emission data were corrected for attenuation and scatter. This resulted from a lower mean value in the uniform area. 2D and 3DRP reconstruction methods showed little effect on the mean activity value, whereas iterative 3D methods gave 7% higher values. Higher RCs were found with iterative reconstruction than with FBP and 3DRP. However, the SOR seemed to be optimal with FBP. SORs were higher with iterative methods and decreased with the number of iterations. CONCLUSION: For studies of small rodents with the Focus 120, (57)Co transmission seems to be the most suitable method for attenuation correction. FORE and 2D reconstruction methods appear to be a good compromise between overall image quality and reconstruction time: OSEM provides the largest contrasts, but FBP provides superior attenuation and scatter correction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Evaluation of18F-UCB-H as a Novel PET Tracer for Synaptic Vesicle Protein 2A in the Brain
Warnock, G. I., Aerts, J., Bahri, M. A., Bretin, F., Lemaire, C., Giacomelli, F., Mievis, F., Mestdagh, N., Buchanan, T., Valade, A., et al. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.136143 · Cited by 85
“Images were reconstructed with all corrections (except scatter (18)) by use of Fourier rebinning and filtered backprojection with a ramp filter cutoff at the Nyquist frequency.”
MethodInfluentialSelf-citationPreclinical radiation dosimetry for the novel SV2A radiotracer [18F]UCB-H
Bretin, F., Warnock, G., Bahri, M. A., Aerts, J., Mestdagh, N., Buchanan, T., Valade, A., Mievis, F., Giacomelli, F., Lemaire, C., et al. (2013) · EJNMMI Research · doi:10.1186/2191-219x-3-35 · Cited by 43
“Accuracy of the technique has been reported to be better than 2% [8].”
MethodSelf-citationPharmacokinetic Characterization of [18F]UCB-H PET Radiopharmaceutical in the Rat Brain
Becker, G., Warnier, C., Serrano, M. E., Bahri, M. A., Mercier, J., Lemaire, C., Salmon, E., Luxen, A., & Plenevaux, A. (2017) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.7b00235 · Cited by 31
Self-citation
Metadata
- Authors
- Bahri, M. A., Plenevaux, A., Warnock, G., Luxen, A., & Seret, A.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2009-09-16
- Volume
- 50
- Issue
- 10
- Pages
- 1730-1738
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2149609428
- Cited by
- 43
- References
- 0
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NEMA NU4-2008 Image Quality Performance Report for the microPET Focus 120 and for Various Transmission and Reconstruction Methods. https://app.cochat.ai/papers/10.2967/jnumed.109.063974
- The paper
- Bahri, M. A., Plenevaux, A., Warnock, G., Luxen, A., & Seret, A. (2009). NEMA NU4-2008 Image Quality Performance Report for the microPET Focus 120 and for Various Transmission and Reconstruction Methods. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.109.063974
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.