CoChat

The α-Camera: A Quantitative Digital Autoradiography Technique Using a Charge-Coupled Device for Ex Vivo High-Resolution Bioimaging of α-Particles

Open access
Bäck, Tom, Jacobsson, Lars · 2010 · Journal of Nuclear Medicine
Cited by 130

The DOI matches its Crossref record.

Abstract

UNLABELLED: Bioconjugates used in internal radiotherapy exhibit heterogeneous distributions in organs and tumors, implying a risk of nonuniform dose distribution in therapeutic applications using α-particle emitters. Tools are required that provide data on the activity distribution for estimation of absorbed dose on a suborgan level. The α-camera is a quantitative imaging technique developed to detect α-particles in tissues ex vivo. The aim of this study was to evaluate the characteristics of this imaging system and to exemplify its potential use in the development of α-radioimmunotherapy. METHODS: The α-camera combines autoradiography with a scintillating technique and optical registration by a charge-coupled device (CCD). The imaging system characteristics were evaluated by measurements of linearity, uniformity, and spatial resolution. The technique was applied for quantitative imaging of (211)At activity distribution in cryosections of tumors, kidney, and whole body. Intratumoral activity distributions of tumor-specific (211)At-MX35-F(ab')(2) were studied at various times after injection. The postinjection activity distributions in the renal cortex and whole kidneys were compared for (211)At-F(ab')(2) and (211)At-IgG trastuzumab. RESULTS: Quantitative analysis of α-camera images demonstrated that the pixel intensity increased linearly with activity in the imaged specimen. The spatial resolution was 35 ± 11 μm (mean ± SD) and the uniformity better than 2%. Kidney cryosections revealed a higher cortex-to-whole kidney ratio for (211)At-F(ab')(2) than for (211)At-IgG (1.38 ± 0.03 and 0.77 ± 0.04, respectively) at 2 h after injection. Nonuniform intratumoral activity distributions were found for tumor-specific (211)At-MX35-F(ab')(2) at 10 min and 7 h after injection; after 21 h, the distribution was more uniform. CONCLUSION: The characteristics of the α-camera are promising, suggesting that this bioimaging system can assist the development, evaluation, and refinement of future targeted radiotherapy approaches using α-emitters. The α-camera provides quantitative data on the activity distribution in tissues on a near-cellular scale and can therefore be used for small-scale dosimetry, improving the prediction of biologic outcomes with α-particles with short path length and high linear energy transfer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.110.077578

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 130

Metadata

Authors
Bäck, T., & Jacobsson, L.
Venue
Journal of Nuclear Medicine
Published
2010-09-16
Volume
51
Issue
10
Pages
1616-1623
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2143509756
Cited by
130
References
0
FWCI
2.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The α-Camera: A Quantitative Digital Autoradiography Technique Using a Charge-Coupled Device for Ex Vivo High-Resolution Bioimaging of α-Particles. https://app.cochat.ai/papers/10.2967/jnumed.110.077578
The paper
Bäck, T., & Jacobsson, L. (2010). The α-Camera: A Quantitative Digital Autoradiography Technique Using a Charge-Coupled Device for Ex Vivo High-Resolution Bioimaging of α-Particles. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.110.077578

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.