CoChat

Implementation and Validation of an Adaptive Template Registration Method for 18F-Flutemetamol Imaging Data

Open access
Lundqvist, Roger, Lilja, Johan, Thomas, Benjamin A., Lötjönen, Jyrki, Villemagne, Victor L., Rowe, Christopher C., Thurfjell, Lennart · 2013 · Journal of Nuclear Medicine
Cited by 112

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

UNLABELLED: The spatial normalization of PET amyloid imaging data is challenging because different white and gray matter patterns of negative (Aβ-) and positive (Aβ+) uptake could lead to systematic bias if a standard method is used. In this study, we propose the use of an adaptive template registration method to overcome this problem. METHODS: Data from a phase II study (n = 72) were used to model amyloid deposition with the investigational PET imaging agent (18)F-flutemetamol. Linear regression of voxel intensities on the standardized uptake value ratio (SUVR) in a neocortical composite region for all scans gave an intercept image and a slope image. We devised a method where an adaptive template image spanning the uptake range (the most Aβ- to the most Aβ+ image) can be generated through a linear combination of these 2 images and where the optimal template is selected as part of the registration process. We applied the method to the (18)F-flutemetamol phase II data using a fixed volume of interest atlas to compute SUVRs. Validation was performed in several steps. The PET-only adaptive template registration method and the MR imaging-based method used in statistical parametric mapping were applied to spatially normalize PET and MR scans, respectively. Resulting transformations were applied to coregistered gray matter probability maps, and the quality of the registrations was assessed visually and quantitatively. For comparison of quantification results with an independent patient-space method, FreeSurfer was used to segment each subject's MR scan and the parcellations were applied to the coregistered PET scans. We then correlated SUVRs for a composite neocortical region obtained with both methods. Furthermore, to investigate whether the (18)F-flutemetamol model could be generalized to (11)C-Pittsburgh compound B ((11)C-PIB), we applied the method to Australian Imaging, Biomarkers and Lifestyle (AIBL) (11)C-PIB scans (n = 285) and compared the PET-only neocortical composite score with the corresponding score obtained with a semimanual method that made use of the subject's MR images for the positioning of regions. RESULTS: Spatial normalization was successful on all scans. Visual and quantitative comparison of the new PET-only method with the MR imaging-based method of statistical parametric mapping indicated that performance was similar in the cortical regions although the new PET-only method showed better registration in the cerebellum and pons reference region area. For the (18)F-flutemetamol quantification, there was a strong correlation between the PET-only and FreeSurfer SUVRs (Pearson r = 0.96). We obtained a similar correlation for the AIBL (11)C-PIB data (Pearson r = 0.94). CONCLUSION: The derived adaptive template registration method allows for robust, accurate, and fully automated quantification of uptake for (18)F-flutemetamol and (11)C-PIB scans without the use of MR imaging data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.112.115006

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 112

Metadata

Authors
Lundqvist, R., Lilja, J., Thomas, B. A., Lötjönen, J., Villemagne, V. L., Rowe, C. C., & Thurfjell, L.
Venue
Journal of Nuclear Medicine
Published
2013-06-05
Volume
54
Issue
8
Pages
1472-1478
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2171573441
Cited by
112
References
14
FWCI
6.80
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.