99mTc-Macroaggregated Albumin Poorly Predicts the Intrahepatic Distribution of 90Y Resin Microspheres in Hepatic Radioembolization
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
UNLABELLED: In hepatic (90)Y radioembolization, pretreatment (99m)Tc-macroaggregated albumin ((99m)Tc-MAA) nuclear imaging is used for lung shunt analysis, evaluation of extrahepatic deposition, and sometimes for treatment planning, using a partition model. A high level of agreement between pretreatment (99m)Tc-MAA distribution and final (90)Y-microsphere distribution is assumed. The aim of this study was to investigate the value of pretreatment (99m)Tc-MAA SPECT to predict intrahepatic posttreatment (90)Y-microsphere distribution. METHODS: Volumes of interest (VOIs) were delineated on pretreatment contrast-enhanced CT or MR images according to Couinaud liver segmentation. All VOIs were registered to the (99m)Tc-MAA SPECT and (90)Y SPECT images. The (99m)Tc-MAA SPECT and (90)Y SPECT activity counts were normalized to the total administered activity of (90)Y. For each VOI, this practice resulted in a predictive amount of (90)Y (MBq/cm(3)) based on (99m)Tc-MAA SPECT in comparison with an actual amount of (90)Y based on (90)Y SPECT. Bland-Altman analysis was used to investigate the agreement of the activity distribution between (99m)Tc-MAA SPECT and (90)Y SPECT. RESULTS: A total of 39 procedures (225 VOIs) in 31 patients were included for analysis. The overall mean difference between pretreatment and posttreatment distribution of activity concentration for all segments was -0.022 MBq/cm(3) with 95% limits of agreement of -0.581 to 0.537 MBq/cm(3) (-28.9 to 26.7 Gy absorbed dose). A difference of >10%, >20%, and >30% of the mean activity per milliliter was found in, respectively, 153 (68%), 97 (43%), and 72 (32%) of the 225 segments. In every (99m)Tc-MAA procedure, at least 1 segment showed an under- or overestimation of >10%. The position of the catheter tip during administrations, as well as the tumor load of the liver segments, significantly influenced the disagreement. CONCLUSION: In current clinical practice, (99m)Tc-MAA distribution does not accurately predict final (90)Y activity distribution. Awareness of the importance of catheter positioning and adherence to specific recommendations may lead to optimization of individualized treatment planning based on pretreatment imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Surgical anatomy and anatomical surgery of the liver
Bismuth, H. (1982) · World Journal of Surgery · doi:10.1007/bf01656368 · Cited by 791 · cited 1×
“Analysis Contrast-enhanced CT or MR pretreatment images were used for liver segmentation according to the Bismuth adaptation of the Couinaud classification of liver anatomy (15).”
MethodHo, S., Lau, W. Y., Leung, T. W. T., Chan, M., Johnson, P. J., & Li, A. K. C. (1997) · European Journal of Nuclear Medicine · doi:10.1007/bf01728766 · Cited by 255
Cited by
Radioembolization of Hepatic Lesions from a Radiobiology and Dosimetric Perspective
Cremonesi, M., Chiesa, C., Strigari, L., Ferrari, M., Botta, F., Guerriero, F., De Cicco, C., Bonomo, G., Orsi, F., Bodei, L., et al. (2014) · Frontiers in Oncology · doi:10.3389/fonc.2014.00210 · Cited by 178
“(30) found discrepancies between 99mTc-MAA images simulating RE and 90Y-Bremsstrahulg SPECT images – post-RE – in patients with a mismatch in catheter tip positioning during administrations.”
BackgroundChiesa, C., Mira, M., Maccauro, M., Spreafico, C., Romito, R., Morosi, C., Camerini, T., Carrara, M., Pellizzari, S., Negri, A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3068-8 · Cited by 164
Metadata
- Authors
- Wondergem, M., Smits, M. L. J., Elschot, M., de Jong, H. W. A. M., Verkooijen, H. M., van den Bosch, M. A. A. J., Nijsen, J. F. W., & Lam, M. G. E. H.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2013-06-07
- Volume
- 54
- Issue
- 8
- Pages
- 1294-1301
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2148464313
- Cited by
- 224
- References
- 4
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 99mTc-Macroaggregated Albumin Poorly Predicts the Intrahepatic Distribution of 90Y Resin Microspheres in Hepatic Radioembolization. https://app.cochat.ai/papers/10.2967/jnumed.112.117614
- The paper
- Wondergem, M., Smits, M. L. J., Elschot, M., de Jong, H. W. A. M., Verkooijen, H. M., van den Bosch, M. A. A. J., Nijsen, J. F. W., & Lam, M. G. E. H. (2013). 99mTc-Macroaggregated Albumin Poorly Predicts the Intrahepatic Distribution of 90Y Resin Microspheres in Hepatic Radioembolization. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.112.117614
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.