Cited by 101Medical Imaging Techniques and ApplicationsLung Cancer Diagnosis and TreatmentAdvanced MRI Techniques and Applications

The DOI matches its Crossref record.

Qualitative and Quantitative Comparison of PET/CT and PET/MR Imaging in Clinical Practice

Open access

Abstract

UNLABELLED: The aim of this study was to prospectively compare whole-body PET/MR imaging and PET/CT, qualitatively and quantitatively, in oncologic patients and assess the confidence and degree of inter- and intraobserver agreement in anatomic lesion localization. METHODS: Fifty patients referred for staging with known cancers underwent PET/CT with low-dose CT for attenuation correction immediately followed by PET/MR imaging with 2-point Dixon attenuation correction. PET/CT scans were obtained according to standard protocols (56 ± 20 min after injection of an average 367 MBq of (18)F-FDG, 150 MBq of (68)Ga-DOTATATE, or 333.8 MBq of (18)F-fluoro-ethyl-choline; 2.5 min/bed position). PET/MR was performed with 5 min/bed position. Three dual-accredited nuclear medicine physicians/radiologists identified the lesions and assigned each to an exact anatomic location. The image quality, alignment, and confidence in anatomic localization of lesions were scored on a scale of 1-3 for PET/CT and PET/MR imaging. Quantitative analysis was performed by comparing the standardized uptake values. Intraclass correlation coefficients and the Wilcoxon signed-rank test were used to assess intra- and interobserver agreement in image quality, alignment, and confidence in lesion localization for the 2 modalities. RESULTS: Two hundred twenty-seven tracer-avid lesions were identified in 50 patients. Of these, 225 were correctly identified on PET/CT and 227 on PET/MR imaging by all 3 observers. The confidence in anatomic localization improved by 5.1% when using PET/MR imaging, compared with PET/CT. The mean percentage interobserver agreement was 96% for PET/CT and 99% for PET/MR imaging, and intraobserver agreement in lesion localization across the 2 modalities was 93%. There was 10% (5/50 patients) improvement in local staging with PET/MR imaging, compared with PET/CT. CONCLUSION: In this first study, we show the effectiveness of whole-body PET/MR imaging in oncology. There is no statistically significant difference between PET/MR imaging and PET/CT in respect of confidence and degree of inter- and intraobserver agreement in anatomic lesion localization. The PET data on both modalities were similar; however, the observed superior soft-tissue resolution of MR imaging in head and neck, pelvis, and colorectal cancers and of CT in lung and mediastinal nodal disease points to future tailored use in these locations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.113.123547

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Systematically different normal organ SUVs have been reported for [18F]FDG, most likely resulting from MR-AC inaccuracies.

    “However, systematically different normal organ SUVs have been reported for [18F]FDG as well, which most likely result from MR-AC inaccuracies [60,65,66].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [66]

    The SUV analysis reports 6%–18% lower SUVs in normal brain, mediastinum, liver, and soft tissue on PET/MR than on PET/CT. It attributes those differences to activity washout between scans, not primarily to MR-based attenuation-correction inaccuracies. The paper discusses attenuation-correction limitations elsewhere, but does not identify them as the likely cause of these normal-organ differences. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 25

  1. 10.1038/sj.bjc.6602464 · DOI
  2. Townsend, 1998, The SMART scanner: a combined PET/CT tomography for clinical oncology, Nucl Sci Symp, 1998., 2, 1170, 10.1109/NSSMIC.1998.774368 · DOI
  3. 10.2967/jnumed.108.045880 · DOI
  4. 10.1102/1470-7330.2007.0014 · DOI
  5. 10.1016/S1470-2045(00)00257-6 · DOI
  6. 10.2967/jnumed.108.051276 · DOI
  7. 10.1007/s00259-008-0951-6 · DOI
  8. 10.1001/jama.290.24.3199 · DOI
  9. 10.1016/j.ejca.2005.10.008 · DOI
  10. 10.1148/radiol.2472071054 · DOI
  11. 10.2214/AJR.11.6460 · DOI
  12. 10.2967/jnumed.108.057182 · DOI
  13. 10.1007/s00259-007-0493-3 · DOI · Paper page
  14. 10.2967/jnumed.108.054726 · DOI
  15. 10.1007/s00259-012-2113-0 · DOI · Paper page
  16. 10.2967/jnumed.109.069112 · DOI
  17. 10.1007/s10334-012-0353-4 · DOI
  18. 10.2967/jnumed.111.098608 · DOI
  19. Paquet, 2004, Within-patient variability of 18F-FDG: standardized uptake values in normal tissues, J Nucl Med., 45, 784
  20. 10.1007/s11307-010-0394-x · DOI
  21. Matthies, 2002, Dual time point 18F-FDG PET for the evaluation of pulmonary nodules, J Nucl Med., 43, 871
  22. 10.1007/s11307-008-0168-x · DOI
  23. 10.1016/j.ejrad.2009.04.059 · DOI
  24. 10.1002/nbm.1357 · DOI
  25. 10.1016/0090-3019(95)00139-5 · DOI

Cited by

Sorted by citations

Metadata

Authors
Al-Nabhani, K. Z., Syed, R., Michopoulou, S., Alkalbani, J., Afaq, A., Panagiotidis, E., O’Meara, C., Groves, A., Ell, P., & Bomanji, J.
Affiliations
University College Hospital (GB)
Venue
Journal of Nuclear Medicine
Published
2013-12-12
Volume
55
Issue
1
Pages
88-94
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2148384441
Cited by
101
References
0
Citations by year
2026: 3 · 2025: 5 · 2024: 4 · 2023: 2 · 2022: 7 · 2021: 7 · 2020: 5 · 2019: 2 · 2018: 4 · 2017: 6 · 2016: 19 · 2015: 22 · 2014: 14 · 2013: 1
FWCI
14.41
Type
journal article
Language
en
Open access
Locations
  • Journal of Nuclear Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • ePrints Soton (University of Southampton) (submittedVersion)
  • UCL Discovery (University College London) (submittedVersion)
Funders
Cancer Research UK (16463)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
Keywords
PET/MR, PET/CT, tumor staging, tumor localization, interobserver agreement, intraobserver agreement, standardized uptake value, 18F-FDG, 68Ga-DOTATATE, soft tissue resolution, image quality, head and neck cancer, pelvic cancer, prostate cancer
MeSH terms
Aged, Female, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Middle Aged, Neoplasm Staging, Pilot Projects, Prospective Studies, Tomography, X-Ray Computed, Reproducibility of Results, Observer Variation, Radiopharmaceuticals, Fluorodeoxyglucose F18, Positron-Emission Tomography, Whole Body Imaging, Multimodal Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review