CoChat

A Comparison of the Imaging Characteristics and Microregional Distribution of 4 Hypoxia PET Tracers

Open access
Carlin, Sean, Zhang, Hanwen, Reese, Megan, Ramos, Nicholas N., Chen, Qing, Ricketts, Sally-Ann · 2014 · Journal of Nuclear Medicine
Cited by 130

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

UNLABELLED: We compared the imaging characteristics and hypoxia selectivity of 4 hypoxia PET radiotracers ((18)F-fluoromisonidazole [(18)F-FMISO], (18)F-flortanidazole [(18)F-HX4], (18)F-fluoroazomycin arabinoside [(18)F-FAZA], and (64)Cu-diacetyl-bis(N4-methylsemicarbazone) [(64)Cu-ATSM]) in a single murine xenograft tumor model condition using small-animal PET imaging and combined ex vivo autoradiography and fluorescence immunohistochemistry. METHODS: Nude mice bearing SQ20b xenograft tumors were administered 1 of 4 hypoxia PET tracers and images acquired 80-90 min after injection. Frozen sections from excised tumors were then evaluated for tracer distribution using digital autoradiography and compared with histologic markers of tumor hypoxia (pimonidazole, carbonic anydrase 9 [CA9]) and vascular perfusion (Hoechst 33342). RESULTS: The highest tumor uptake was observed with (64)Cu-ATSM (maximum standardized uptake values [SUV(max)], 1.26 ± 0.13) and the lowest with (18)F-FAZA (SUVmax, 0.41 ± 0.24). (18)F-FMISO and (18)F-HX4 had similar intermediate tumor uptake (SUV(max), 0.76 ± 0.38 and 0.65 ± 0.19, respectively). Digital autoradiographs of hypoxia tracer distribution were compared pixel by pixel with images of immunohistochemistry stains. The fluorinated nitroimidazoles all showed radiotracer uptake increasing with pimonidazole and CA9 staining. (64)Cu-ATSM showed the opposite pattern, with highest radiotracer uptake observed in regions with the lowest pimonidazole and CA9 staining. CONCLUSION: The fluorinated nitroimidazoles showed similar tumor distributions when compared with immunohistochemistry markers of hypoxia. Variations in tumor standardized uptake value and normal tissue distribution may determine the most appropriate clinical setting for each tracer. (64)Cu-ATSM showed the highest tumor accumulation and little renal clearance. However, the lack of correlation between (64)Cu-ATSM distribution and immunohistochemistry hypoxia markers casts some doubt on the hypoxia selectivity of (64)Cu-ATSM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.113.126615

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 130

Metadata

Authors
Carlin, S., Zhang, H., Reese, M., Ramos, N. N., Chen, Q., & Ricketts, S.-A.
Venue
Journal of Nuclear Medicine
Published
2014-02-03
Volume
55
Issue
3
Pages
515-521
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2011766836
Cited by
130
References
3
FWCI
13.23
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of the Imaging Characteristics and Microregional Distribution of 4 Hypoxia PET Tracers. https://app.cochat.ai/papers/10.2967/jnumed.113.126615
The paper
Carlin, S., Zhang, H., Reese, M., Ramos, N. N., Chen, Q., & Ricketts, S.-A. (2014). A Comparison of the Imaging Characteristics and Microregional Distribution of 4 Hypoxia PET Tracers. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.113.126615

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.