CoChat

A Semiautomated Method for Quantification of F 18 Florbetapir PET Images

Open access
Joshi, Abhinay D., Pontecorvo, Michael J., Lu, Ming, Skovronsky, Daniel M., Mintun, Mark A., Devous, Michael D. · 2015 · Journal of Nuclear Medicine
Cited by 92

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

UNLABELLED: PET amyloid imaging is increasingly used in research trials related to Alzheimer disease and has potential as a quantitative biomarker. This study had 3 objectives: first, to describe a semiautomated quantitative method that does not require subject-specific MR imaging scans for estimating F 18 Florbetapir plaque binding using 10-min PET images; second, to evaluate the method's accuracy for identifying positive and negative scans; and third, to correlate derived standardized uptake value ratios to neuropathologic measures of amyloid. METHODS: The F 18 Florbetapir PET images are initially converted to Montreal Neurologic Institute brain atlas space using an internally developed PET target F 18 Florbetapir template. Subsequently, a single mean cortical standardized uptake value ratio (mcSUVr) is calculated from the mean standardized uptake value of 6 cortical regions normalized to a reference region. Four reference regions were explored: whole cerebellum, cerebellar gray matter, pons, and centrum semiovale. The performance of the resultant mcSUVrs were evaluated in 74 young cognitively normal subjects (age < 50 y) with a negligible likelihood of amyloid β pathology, and in 59 deceased subjects with autopsy-based amyloid β neuritic plaque measure who underwent F 18 Florbetapir PET imaging before death. RESULTS: Significant correlations were obtained between mcSUVrs and 3 different pathologic measures of amyloid deposition at autopsy using all 4 reference regions, with the whole-cerebellum mcSUVr correlating most strongly across pathologic measures (r = 0.71-0.75, P < 0.0001). Using the whole-cerebellum mcSUVr and a threshold mcSUVr of less than 1.10, 100% of young cognitively normal subjects were correctly classified as amyloid-negative (mcSUVr range, 0.87-1.08). Similarly, 20 of 20 autopsy-negative subjects showed mcSUVrs of 1.10 or less, whereas 38 of 39 pathology-verified amyloid-positive subjects had mcSUVrs of more than 1.10. CONCLUSION: This semiautomated F 18 Florbetapir PET quantification method yielded mcSUVrs that significantly correlated with measures of amyloid pathology at autopsy. The method also effectively discriminated autopsy-identified amyloid-positive and -negative cases using a whole-cerebellum mcSUVr threshold of 1.10.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.114.153494

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 92

Metadata

Authors
Joshi, A. D., Pontecorvo, M. J., Lu, M., Skovronsky, D. M., Mintun, M. A., & Devous, M. D.
Venue
Journal of Nuclear Medicine
Published
2015-09-03
Volume
56
Issue
11
Pages
1736-1741
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2213225786
Cited by
92
References
7
FWCI
7.24
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Semiautomated Method for Quantification of F 18 Florbetapir PET Images. https://app.cochat.ai/papers/10.2967/jnumed.114.153494
The paper
Joshi, A. D., Pontecorvo, M. J., Lu, M., Skovronsky, D. M., Mintun, M. A., & Devous, M. D. (2015). A Semiautomated Method for Quantification of F 18 Florbetapir PET Images. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.114.153494

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.