Reliability of PET/CT Shape and Heterogeneity Features in Functional and Morphologic Components of Non–Small Cell Lung Cancer Tumors: A Repeatability Analysis in a Prospective Multicenter Cohort
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
The main purpose of this study was to assess the reliability of shape and heterogeneity features in both the PET and the low-dose CT components of PET/CT. A secondary objective was to investigate the impact of image quantization. Methods: A Health Insurance Portability and Accountability Act–compliant secondary analysis of deidentified prospectively acquired PET/CT test–retest datasets of 74 patients from multicenter Merck and American College of Radiology Imaging Network trials was performed. Metabolically active volumes were automatically delineated on PET with a fuzzy locally adaptive bayesian algorithm. Software was used to semiautomatically delineate the anatomic volumes on the low-dose CT component. Two quantization methods were considered: a quantization into a set number of bins (quantization B) and an alternative quantization with bins of fixed width (quantization W). Four shape descriptors, 10 first-order metrics, and 26 textural features were evaluated. Bland–Altman analysis was used to quantify repeatability. Features were subsequently categorized as very reliable, reliable, moderately reliable, or poorly reliable with respect to the corresponding volume variability. Results: Repeatability was highly variable among features. Numerous metrics were identified as poorly or moderately reliable. Others were reliable or very reliable in both modalities and in all categories (shape and first-, second-, and third-order metrics). Image quantization played a major role in feature repeatability. Features were more reliable in PET with quantization B, whereas quantization W showed better results in CT. Conclusion: The test–retest repeatability of shape and heterogeneity features in PET and low-dose CT varied greatly among metrics. The level of repeatability also depended strongly on the quantization step, with different optimal choices for each modality. The repeatability of PET and low-dose CT features should be carefully considered when selecting metrics to build multiparametric models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084 · cited 1×
“Radiomics denotes the extraction of intensity, shape, and heterogeneity features from medical images (2).”
BackgroundDecoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132 · cited 2×
“3D shape descriptors were included, such as sphericity, irregularity or major axis (4,28) .”
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777 · cited 1×
“This has been estimated at 615% to 30% for SUV and volume (12,13).”
BackgroundVallières, M., Freeman, C. R., Skamene, S. R., & El Naqa, I. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/14/5471 · Cited by 897 · cited 1×
“2 nd -order metrics from grey-level co-occurrence matrix (GLCM) and neighborhood grey-tone difference matrix (NGTDM), and 3 rd -order metrics from grey-level zone size matrix were calculated in a single matrix considering all 13 orientations simultaneously (30,31) .”
Shankar, L. K., Hoffman, J. M., Bacharach, S. L., Graham, M. M., Karp, J. S., Lammertsma, A. A., Larson, S. M., Mankoff, D. A., Siegel, B. A., den Abbeele, A. V., et al. (2006) · PubMed · Cited by 765
Self-citationCharacterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475 · cited 1×
“…their repeatability in PET with FDG or fluorine-18 fluorothymidine (8,14–17) and in Finally, it has been shown recently that the image quantization step in the calculation of textural features can have an impact on the relationship to other parameters (3) and on the repeatability (17,22) .”
Self-citationHatt, M., Majdoub, M., Vallières, M., Tixier, F., Le Rest, C. C., Groheux, D., Hindié, E., Martineau, A., Pradier, O., Hustinx, R., et al. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.144055 · Cited by 438 · cited 2×
“Quantization was performed in a set number of bins B (denoted from here onward as quantization B), as previously recommended (14,18,30,32) using Equation 1:”
MethodSelf-citationLeijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812798 · Cited by 427 · cited 2×
“Regarding shape and heterogeneity features, our results confirm prior findings in PET (8,14–17) .”
Leijenaar, R. T. H., Nalbantov, G., Carvalho, S., van Elmpt, W. J. C., Troost, E. G. C., Boellaard, R., Aerts, H. J. W. L., Gillies, R. J., & Lambin, P. (2015) · Scientific Reports · doi:10.1038/srep11075 · Cited by 426
Galavis, P. E., Hollensen, C., Jallow, N., Paliwal, B., & Jeraj, R. (2010) · Acta Oncologica · doi:10.3109/0284186x.2010.498437 · Cited by 344
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Self-citationRadiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
Machine and deep learning methods for radiomics
Avanzo, M., Wei, L., Stancanello, J., Vallières, M., Rao, A., Morin, O., Mattonen, S. A., & El Naqa, I. (2020) · Medical Physics · doi:10.1002/mp.13678 · Cited by 605
Beyond imaging: The promise of radiomics
Avanzo, M., Stancanello, J., & El Naqa, I. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.05.071 · Cited by 483
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
Assessing robustness of radiomic features by image perturbation
Zwanenburg, A., Leger, S., Agolli, L., Pilz, K., Troost, E. G. C., Richter, C., & Löck, S. (2019) · Scientific Reports · doi:10.1038/s41598-018-36938-4 · Cited by 242
Repeatability of Multiparametric Prostate MRI Radiomics Features
Schwier, M., van Griethuysen, J., Vangel, M. G., Pieper, S., Peled, S., Tempany, C., Aerts, H. J. W. L., Kikinis, R., Fennessy, F. M., & Fedorov, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-45766-z · Cited by 237
Papadimitroulas, P., Brocki, L., Christopher Chung, N., Marchadour, W., Vermet, F., Gaubert, L., Eleftheriadis, V., Plachouris, D., Visvikis, D., Kagadis, G. C., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.009 · Cited by 226
“…radiomic features because they have been identified to be unreliable (i.e., exhibit unreasonable variations in response to small variability of acquisition and reconstruction settings [130] or in a test – retest framework [148] before even considering them in any statistical analysis [149].”
BackgroundSelf-citationZhang, J., Zhao, X., Zhao, Y., Zhang, J., Zhang, Z., Wang, J., Wang, Y., Dai, M., & Han, J. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04592-1 · Cited by 205
Radiomics feature reliability assessed by intraclass correlation coefficient: a systematic review
Xue, C., Yuan, J., Lo, G. G., Chang, A. T. Y., Poon, D. M. C., Wong, O. L., Zhou, Y., & Chu, W. C. W. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-86 · Cited by 177
Dissaux, G., Visvikis, D., Da-ano, R., Pradier, O., Chajon, E., Barillot, I., Duvergé, L., Masson, I., Abgral, R., Santiago Ribeiro, M.-J., et al. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.228106 · Cited by 172
Self-citationChallenges and Promises of PET Radiomics
Cook, G. J. R., Azad, G., Owczarczyk, K., Siddique, M., & Goh, V. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.12.268 · Cited by 167
Texture analysis of medical images for radiotherapy applications
Scalco, E., & Rizzo, G. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160642 · Cited by 165
Metadata
- Authors
- Desseroit, M.-C., Tixier, F., Weber, W. A., Siegel, B. A., Cheze Le Rest, C., Visvikis, D., & Hatt, M.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2016-10-20
- Volume
- 58
- Issue
- 3
- Pages
- 406-411
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2528857716
- Cited by
- 160
- References
- 34
- FWCI
- 14.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.