The DOI matches its Crossref record.
Dose Mapping After Endoradiotherapy with 177Lu-DOTATATE/DOTATOC by a Single Measurement After 4 Days
Open accessAbstract
Dosimetry of organs and tumors helps to assess risks and benefit of treatment with 177Lu-DOTATATE/DOTATOC. However, it is often not performed in clinical routine because of additional efforts, the complexity of data collection and analysis, and the additional burden for the patients. Aiming at a simplification of dosimetry, we analyzed the accuracy of a theoretically substantiated approximation, which allows the calculation of absorbed doses from a single measurement of the abdominal activity distribution. Methods: Activity kinetics were retrospectively assessed from planar images in 29 patients with neuroendocrine tumors (NETs; n = 21) or meningioma (n = 8) after the administration of 177Lu-DOTATATE (n = 22) or 177Lu-DOTATOC (n = 7). Mono- or biexponential functions were fitted to measured data in 54 kidneys, 25 livers, 27 spleens, and 30 NET lesions. It was evaluated for each fit function how well the integral over time was represented by an approximation calculated as the product of the time tl of a single measurement, the expected reading at time tl, and the factor 2/ln(2). Tissue-specific deviations of the approximation from the time integral were calculated for time points tl of 24, 48, 72, 96, 120, and 144 h. Results: The correlation between time integral and approximation improved with increasing time tl. Pearson r exceeded 0.95 for a tl of 96 h or more in all tissues. The lowest maximum errors were observed at a tl of 96 h, with deviations of the approximation from the time integral of median +5% (range, −9% to +17%) for kidneys, +6% (range, −7% to +12%) for livers, +8% (range, +2% to +20%) for spleens, and +6% (range, −11% to +16%) for NET lesions. Accuracy was reduced for measurements after 72 or 120 h. For measurements after 24, 48, and 144 h, the approximation led to large deviations for some of the patients, in particular unacceptable underestimates of the absorbed dose to the kidneys. Conclusion: A single quantitative measurement of the abdominal activity concentration by SPECT/CT 4 d after the administration of 177Lu-DOTATATE/DOTATOC provides a 3-dimensional dose map and can be used to estimate the doses actually absorbed in the treatment cycle with minor additional resources and effort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
EANM procedure guidelines for radionuclide therapy with 177Lu-labelled PSMA-ligands (177Lu-PSMA-RLT)
Kratochwil, C., Fendler, W. P., Eiber, M., Baum, R., Bozkurt, M. F., Czernin, J., Delgado Bolton, R. C., Ezziddin, S., Forrer, F., Hicks, R. J., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04485-3 · Cited by 387
Self-citationDel Prete, M., Buteau, F.-A., Arsenault, F., Saighi, N., Bouchard, L.-O., Beaulieu, A., & Beauregard, J.-M. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4209-7 · Cited by 184
Peters, S. M. B., Privé, B. M., de Bakker, M., de Lange, F., Jentzen, W., Eek, A., Muselaers, C. H. J., Mehra, N., Witjes, J. A., Gotthardt, M., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05471-4 · Cited by 88
Metadata
- Authors
- Hänscheid, H., Lapa, C., Buck, A. K., Lassmann, M., & Werner, R. A.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2017-06-06
- Volume
- 59
- Issue
- 1
- Pages
- 75-81
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2622435004
- Cited by
- 219
- References
- 0
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dose Mapping After Endoradiotherapy with 177Lu-DOTATATE/DOTATOC by a Single Measurement After 4 Days. https://app.cochat.ai/papers/10.2967/jnumed.117.193706
- The paper
- Hänscheid, H., Lapa, C., Buck, A. K., Lassmann, M., & Werner, R. A. (2018). Dose Mapping After Endoradiotherapy with 177Lu-DOTATATE/DOTATOC by a Single Measurement After 4 Days. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.117.193706
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.