CoChat

Validation of Noninvasive Tracer Kinetic Analysis of 18F-Florbetaben PET Using a Dual–Time-Window Acquisition Protocol

Open access
Bullich, Santiago, Barthel, Henryk, Koglin, Norman, Becker, Georg A., De Santi, Susan, Jovalekic, Aleksandar, Stephens, Andrew W., Sabri, Osama · 2018 · Journal of Nuclear Medicine
Cited by 42

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Accurate amyloid PET quantification is necessary for monitoring amyloid-β accumulation and response to therapy. Currently, most of the studies are analyzed using the static SUV ratio (SUVR) approach because of its simplicity. However, this approach may be influenced by changes in cerebral blood flow (CBF) or radiotracer clearance. Full tracer kinetic models require arterial blood sampling and dynamic image acquisition. The objectives of this work were, first, to validate a noninvasive kinetic modeling approach for 18F-florbetaben PET using an acquisition protocol with the best compromise between quantification accuracy and simplicity and, second, to assess the impact of CBF changes and radiotracer clearance on SUVRs and noninvasive kinetic modeling data in 18F-florbetaben PET. Methods: Using data from 20 subjects (10 patients with probable Alzheimer dementia and 10 healthy volunteers), the nondisplaceable binding potential (BPND) obtained from the full kinetic analysis was compared with the SUVR and with noninvasive tracer kinetic methods (simplified reference tissue model and multilinear reference tissue model 2). Various approaches using shortened or interrupted acquisitions were compared with the results of the full acquisition (0–140 min). Simulations were performed to assess the effect of CBF and radiotracer clearance changes on SUVRs and noninvasive kinetic modeling outputs. Results: An acquisition protocol using time windows of 0–30 and 120–140 min with appropriate interpolation of the missing time points provided the best compromise between patient comfort and quantification accuracy. Excellent agreement was found between BPND obtained using the full protocol and BPND obtained using the dual-window protocol (for multilinear reference tissue model 2, BPND [dual-window] = 0.01 + 1.00·BPND [full], R2 = 0.97; for simplified reference tissue model, BPND [dual-window] = 0.05 + 0.92·BPND [full], R2 = 0.93). Simulations showed a limited impact of CBF and radiotracer clearance changes on multilinear reference tissue model parameters and SUVR. Conclusion: This study demonstrated accurate noninvasive kinetic modeling of 18F-florbetaben PET data using a dual-window acquisition, thus providing a good compromise between quantification accuracy, scan duration, and patient burden. The influence of CBF and radiotracer clearance changes on amyloid-β load estimates was small. For most clinical research applications, the SUVR approach is appropriate. However, for longitudinal studies in which maximum quantification accuracy is desired, this noninvasive dual-window acquisition with kinetic analysis is recommended.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.117.200964

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Bullich, S., Barthel, H., Koglin, N., Becker, G. A., De Santi, S., Jovalekic, A., Stephens, A. W., & Sabri, O.
Venue
Journal of Nuclear Medicine
Published
2017-11-24
Volume
59
Issue
7
Pages
1104-1110
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2769234458
Cited by
42
References
2
FWCI
1.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.