CoChat

Characterization of 3 Novel Tau Radiopharmaceuticals, 11 C-RO-963, 11 C-RO-643, and 18 F-RO-948, in Healthy Controls and in Alzheimer Subjects

Open access
Wong, Dean F., Comley, Robert A., Kuwabara, Hiroto, Rosenberg, Paul B., Resnick, Susan M., Ostrowitzki, Susanne, Vozzi, Cristina, Boess, Frank, Oh, Esther, Lyketsos, Constantine G., Honer, Michael, Gobbi, Luca, Klein, Gregory, George, Noble, Gapasin, Lorena, Kitzmiller, Kelly, Roberts, Josh, Sevigny, Jeff, Nandi, Ayon, Brasic, James, Mishra, Chakradhar, Thambisetty, Madhav, Moghekar, Abhay, Mathur, Anil, Albert, Marilyn, Dannals, Robert F., Borroni, Edilio · 2018 · Journal of Nuclear Medicine
Cited by 103

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

11C-RO-963, 11C-RO-643, and 18F-RO-948 (previously referred to as 11C-RO6924963, 11C-RO6931643, and 18F-RO6958948, respectively) have been reported as promising PET tracers for tau imaging based on in vitro and preclinical PET data. Here we describe the first, to our knowledge, human evaluation of these novel radiotracers. Methods: Amyloid PET–positive Alzheimer disease (AD) subjects and younger controls each received 2 different tau tracers. Dynamic 90-min scans were obtained after bolus injection of 11C-RO-963, 11C-RO-643, or 18F-RO-948. Arterial blood sampling was performed on 11 healthy controls and 11 AD subjects. Regions were defined on MR images, and PET data were quantified by plasma reference graphical analysis (for total distribution volume) and target cerebellum ratio (SUV ratios of 60- to 90-min frames). SUV ratio images were also analyzed voxelwise. Five older controls each underwent 2 scans with 18F-RO-948 for evaluation of test–retest variability. Four AD subjects underwent a repeated 18F-RO-948 scan 6–22 mo after the first scan. Six additional healthy controls (3 men and 3 women; age range, 41–67 y) each underwent 1 whole-body dosimetry scan with 18F-RO-948. Results: In younger controls, SUVpeak was observed in the temporal lobe with values of approximately 3.0 for 11C-RO-963, 1.5 for 11C-RO-643, and 3.5 for 18F-RO-948. Over all brain regions and subjects, the trend was for 18F-RO-948 to have the highest SUVpeak, followed by 11C-RO-963 and then 11C-RO-643. Regional analysis of SUV ratio and total distribution volume for 11C-RO-643 and 18F-RO-948 clearly discriminated the AD group from the healthy control groups. Compartmental modeling confirmed that 11C-RO-643 had lower brain entry than either 11C-RO-963 or 18F-RO-948 and that 18F-RO-948 showed better contrast between (predicted) areas of high versus low tau accumulation. Thus, our subsequent analysis focused on 18F-RO-948. Both voxelwise and region-based analysis of 18F-RO-948 binding in healthy controls versus AD subjects revealed multiple areas where AD subjects significantly differed from healthy controls. Of 22 high-binding regions, 13 showed a significant group difference (after ANOVA, F(1,21) = 45, P < 10−5). Voxelwise analysis also revealed a set of symmetric clusters where AD subjects had higher binding than healthy controls (threshold of P < 0.001, cluster size > 50). Conclusion:18F-RO-948 demonstrates characteristics superior to 11C-RO-643 and 11C-RO-963 for characterization of tau pathology in AD. Regional binding data and kinetic properties of 18F-RO-948 compare favorably with other existing tau PET tracers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.118.209916

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 103

Metadata

Authors
Wong, D. F., Comley, R. A., Kuwabara, H., Rosenberg, P. B., Resnick, S. M., Ostrowitzki, S., Vozzi, C., Boess, F., Oh, E., Lyketsos, C. G., Honer, M., Gobbi, L., Klein, G., George, N., Gapasin, L., Kitzmiller, K., Roberts, J., Sevigny, J., Nandi, A., Brasic, J., Mishra, C., Thambisetty, M., Moghekar, A., Mathur, A., Albert, M., Dannals, R. F., & Borroni, E.
Venue
Journal of Nuclear Medicine
Published
2018-05-04
Volume
59
Issue
12
Pages
1869-1876
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2951772320
Cited by
103
References
12
FWCI
9.20
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization of 3 Novel Tau Radiopharmaceuticals, 11 C-RO-963, 11 C-RO-643, and 18 F-RO-948, in Healthy Controls and in Alzheimer Subjects. https://app.cochat.ai/papers/10.2967/jnumed.118.209916
The paper
Wong, D. F., Comley, R. A., Kuwabara, H., Rosenberg, P. B., Resnick, S. M., Ostrowitzki, S., Vozzi, C., Boess, F., Oh, E., Lyketsos, C. G., Honer, M., Gobbi, L., Klein, G., George, N., Gapasin, L., Kitzmiller, K., Roberts, J., Sevigny, J., Nandi, A., . . . Borroni, E. (2018). Characterization of 3 Novel Tau Radiopharmaceuticals, 11 C-RO-963, 11 C-RO-643, and 18 F-RO-948, in Healthy Controls and in Alzheimer Subjects. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.118.209916

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.