Time to Prepare for Risk Adaptation in Lymphoma by Standardizing Measurement of Metabolic Tumor Burden
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Increased tumor burden is associated with inferior outcomes in many lymphoma subtypes. Surrogates of tumor burden that are easy to measure, such as the maximum tumor dimension of the bulkiest lesion on CT, have been used as prognostic indices for many years. Recently, total metabolic tumor volume (MTV) and tumor lesion glycolysis have emerged as promising and robust biomarkers of outcome in various lymphomas. The median MTV and the optimal cutoffs to separate patients into risk groups in a study population are, however, highly dependent on the population characteristics and the delineation method used to outline tumor on the PET image. This issue has precluded the use of MTV for risk stratification in trials and clinical practice. Standardization of the methodology is timely to allow the potential for risk adaptation to be explored in addition to response adaptation using PET. Meetings between representatives from research groups active in the field were held under the auspices of the PET International Lymphoma and Myeloma Workshop. A summary of those discussions, which included a review of the literature and a practical assessment of methods used for outlining, including various software options, is presented. Finally, a proposal is made to perform a technical validation of MTV measurement enabling benchmark reference ranges to be derived for published delineation approaches used for outlining with various software. This process would require collation of representative imaging data sets of the most common lymphoma subtypes; agreement on pragmatic criteria for the selection of lesions; generation of a range of MTVs, with consensus to be reached on final contours in a training set; and development of automated software solutions with a set of minimum functionalities to reduce measurement variability. Methods developed in the above training exercise could then be applied to another data set, with a final set of contours and values generated. This final data set would provide a benchmark against which end-users could test their ability to measure MTVs that are consistent with expected values. The data set and automated software solutions could be shared with manufacturers with the aim of including these in standard workflows to allow standardization of MTV measurement across the world.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303 · cited 1×
“Solutions to deal with uncertainties in technical and biologic factors (41) are included in international guidance (42) and are commonly applied in trials and clinical practice for tumor imaging.”
BackgroundSelf-citationIlyas, H., Mikhaeel, N. G., Dunn, J. T., Rahman, F., Møller, H., Smith, D., & Barrington, S. F. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3953-z · Cited by 150 · cited 4×
“0 (45), or SUV relative to a reference region such as the liver or mediastinum (46,47) as suggested in PERCIST (48).”
BackgroundMethodInfluentialSelf-citationCottereau, A.-S., Hapdey, S., Chartier, L., Modzelewski, R., Casasnovas, O., Itti, E., Tilly, H., Vera, P., Meignan, M. A., & Becker, S. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.180406 · Cited by 64 · cited 1×
“More complex image-processing methods, including gradient thresholds based on changes in the intensity of uptake at the edges of lesions (52); sourceto-background–corrected contours (53); and statistical methods such as clustering (54), fuzzy locally adaptive Bayesian (55), and others, have been proposed but not appli…”
MethodSelf-citation
Cited by
Vercellino, L., Di Blasi, R., Kanoun, S., Tessoulin, B., Rossi, C., D'Aveni-Piney, M., Obéric, L., Bodet-Milin, C., Bories, P., Olivier, P., et al. (2020) · Blood Advances · doi:10.1182/bloodadvances.2020003001 · Cited by 410
Self-citation
Metadata
- Authors
- Barrington, S. F., & Meignan, M.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2019-04-06
- Volume
- 60
- Issue
- 8
- Pages
- 1096-1102
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2927995861
- Cited by
- 158
- References
- 3
- FWCI
- 13.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.